Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Development Package
Address:
6501 E GRANT RD
Address NEW:
6501 E GRANT RD
Apply Date:
11/27/2013
Applicant:
Description:
INSITE GRANT ROAD

Permit Reviews

Permit Number - DP13-0236
Permit Status: Complete
Permit Description: INSITE GRANT ROAD
Start Date Submittal Complete Date Status  
04/16/2014 DEV PKG - RESUBMITTAL 06/02/2014 COMPLETED Review Details
06/02/2014 DEV PKG - RESUBMITTAL 06/17/2014 COMPLETED Review Details
06/17/2014 DEV PKG - RESUBMITTAL 10/28/2014 COMPLETED Review Details
10/28/2014 DEV PKG - REVISION 10/28/2014 ACTIVE Review Details
11/27/2013 DEV PKG - OK TO SUBMIT 11/27/2013 COMPLETED Review Details
12/02/2013 DEV PKG 04/16/2014 COMPLETED Review Details

Completed Inspections

Permit Status: Complete
Permit Number: DP13-0236
Permit Description: INSITE GRANT ROAD
Total Completed Inspections - 7
Date Description Inspector Results Comments
10/09/2014 SITE - Stormwater Follow-up Passed {Activity date: 10/09/2014; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - }
10/09/2014 SITE - Stormwater Final Inspection Passed {Activity date: 10/09/2014; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - }
10/09/2014 SITE - Stormwater Setup and Controls Passed {Activity date: 10/09/2014; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - }
10/09/2014 PDSD Engineering Division Pre-Construction SITE Passed {Activity date: 10/09/2014; Status: Approved; Inspector: RLEDONNE; Comment: Entered by RLEDONN1 - }
02/12/2020 ENGR Grading Final Passed {Activity date: 02/12/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - } ; {Activity date: 10/28/2014; Status: Continued; Inspector: ELIEIBOLD; Comment: Entered by ARUIZ1 - Tier 1 Revision accepted 28OCT14 by E/L/Z for rear of bldg to provide 4' roof scuppers, 4'x4' splash pads w/ 6" rock & FF, & cautionary stripping on portion of s/w under N scupper per dtls provided by Jeff Hunt PE & D M Pavlovic PE.
}
09/22/2020 PDSD Site/Engineering Division - Landscaping Passed {Activity date: 09/22/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by DROBERT5 - }
09/22/2020 ENGR Engineering Final Passed {Activity date: 09/22/2020; Status: Approved; Inspector: DROBERTS; Comment: Entered by RSALDAT1 - IS APPROVED AT THIS TIME} ; {Activity date: 02/14/2020; Status: Not ready for Inspection; Inspector: DROBERTS; Comment: Entered by DMERANZ1 - THIS IS A SITE VISIT ONLY TO GATHER INFORMATION TO DETERMINE IF THE SITE CONDITIONS HAVE BEEN MET AS SHOWN ON THE APPROVED PLANS. THIS INSPECTION WILL CONTINUE NEXT WEEK ONCE I CAN LOOK AT THE APPROVED PLANS FOR THIS SITE.} ; {Activity date: 10/31/2014; Status: Correction Required; Inspector: DROBERTS; Comment: Entered by DROBERT5 - WALKED THE SITE WITH E.O.R. AND RON LE DONNE AND LOOKED OVER THE ISSUES THAT NEED TO BE ADDRESSED AT THIS TIME. THE FOLLOWING ITEMS HAVE BEEN DISCUSSED AND WILL NEED TO BE ADDRESSED PRIOR TO THE FINAL:
1) ADDRESS THE MISSING DG IN ALL AREAS THAT HAVE NOT BEEN COMPLETED AT THIS TIME. THIS WILL INCLUDE ALL AREAS THAT HAVE BEEN DISTURBED BY THE CONTRACTOR AND THIS WILL INCLUDE THE DISTURBED WEST OF THE SITE. 2) CLEAN UP ALL MATERIALS THAT HAVE BEEN LEFT ON THIS SITE, THIS WILL INCLUDE BUT IS NOT LIMITED TO CONCRETE SPILLS, MORTAR SPILLS, TRASH AND DEBRIS IN OR ADJACENT TO THE WASH, AND A 55 GALLON DRUM AT THE NORTHWEST CORNER OF THE SITE. 3) MAKE NECESSARY CHANGES TO THE PLANTS AS REQUIRED BY THE REZONING CONDITIONS. THIS WILL INCLUDE REPLACING ANY MISSING PLANTS OR TREES THAT WERE SPECIFIED TO BE SAVED DURING CONSTRUCTION. 4) GENERAL SITE CLEANUP TOO ENSURE THAT ALL CONSTRUCTION TRASH AND DEBRIS HAS BEEN ELIMINATED FROM THIS SITE. ALL CURRENT DUMPSTERS NEED TO BE PLACED INTO AN AREA SO THAT THEY DO NOT CONFLICT WITH PARKING THAT IS REQUIRED FOR USE.

IT WAS NOTED THAT THE BICYCLE PARKING DOES NOT MEET THE ZONING STANDARDS FOR THIS AREA. CHECK WITH THE ZONING REVIEWER TO VERIFY WHERE THE SPACES NEED TO BE PLACED SO THAT THEY ARE IN COMPLIANCE. CURRENTLY ONE IS IN QUESTION AT THE SOUTHEAST CORNER OF THE BUILDING, THERE IS NOT ENOUGH CLEANCE BETWEEN THE RACK AND THE BUILDING TO ALLOW FOR PARKING ON BOTH SIDES. VERIFY THAT THE CORRECT SPACES HAVE BEEN PROVIDED AND IN PROPER LOCATIONS. MAKE ALL NECESSARY CHANGES TO THE APPROVED PLANS FOR THIS SITE PRIOR TO SCHEDULING THE FINAL INSPECTION FOR THIS SITE.}

Documents

File Name Document Type  
001_ELEVATIONS_A4.TIF DEVELOPMENT PACKAGE VIEW
002_TRASH ENCLOSURE DETAILS_A1.1.TIF DEVELOPMENT PACKAGE VIEW
003_COVER SHEET_1 OF 16.TIF DEVELOPMENT PACKAGE VIEW
004_REZONING CONDITIONS_2 OF 16.TIF DEVELOPMENT PACKAGE VIEW
005_SITE_3 OF 16.TIF DEVELOPMENT PACKAGE VIEW
006_GRADING_4 OF 16.TIF DEVELOPMENT PACKAGE VIEW
007_UTILITIES_5 OF 16.TIF DEVELOPMENT PACKAGE VIEW
008_DETAILS / SURVEY NOTES_6 OF 16.TIF DEVELOPMENT PACKAGE VIEW
009_SWPPP SITE_7 OF 16.TIF DEVELOPMENT PACKAGE VIEW
010_LANDSCAPE COVER SHEET_8 OF 16.TIF DEVELOPMENT PACKAGE VIEW
011_LANDSCAPE_9 OF 16.TIF DEVELOPMENT PACKAGE VIEW
012_IRRIGATION_10 OF 16.TIF DEVELOPMENT PACKAGE VIEW
013_RAINWATER HARVESTING_11 OF 16.TIF DEVELOPMENT PACKAGE VIEW
014_LANDSCAPE DETAILS_12 OF 16.TIF DEVELOPMENT PACKAGE VIEW
015_IRRIGATION DETAILS_13 OF 16.TIF DEVELOPMENT PACKAGE VIEW
016_IRRIGATION DETAILS_14 OF 16.TIF DEVELOPMENT PACKAGE VIEW
017_PHOTOMETRIC_15 OF 16.TIF DEVELOPMENT PACKAGE VIEW
018_EXISTING CONDITIONS SITE_16 OF 16.TIF DEVELOPMENT PACKAGE VIEW
DP13-0236 SWG.PDF DOCUMENTS VIEW
SWG TUCSON DISTRICT CONTACT INFO-MAP-STANDBY.PDF DOCUMENTS VIEW
DP13-0236 PAG.PDF DOCUMENTS VIEW
PAG2.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW