Permit Number: DP13-0230
Parcel: 133369670

Review Status: Completed

Review Details: DEV PKG - RESUBMITTAL

Permit Number - DP13-0230
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/04/2014 AROMERO4 START PLANS SUBMITTED Completed
04/08/2014 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Passed Approved during first review.
04/08/2014 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved first review was informational only
04/14/2014 DAVID RIVERA ZONING REVIEW Approv-Cond FROM: David Rivera
Principal Planner

PROJECT: DP13-030
9675 E Broadway Boulevard
Development Package for Expansion of A-Family Storage

TRANSMITTAL DATE: April 14, 2014

DUE DATE: May 2, 2014

COMMENTS: Zoning is conditionally approving the DP subject to including in the next submittal of the DP, the color renderings as requested by the previous comment 24 noted now as comment 01.


2-06.4.0 CONTENT REQUIREMENTS

2-06.4.7.A.8 - For development package documents provide:

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.



01. Follow-up Comment to previous comment 24: The requested color renderings were not included with the current submittal of the DP. Submit copies of the renderings with the next submittal.

2-06.4.9.U - Indicate graphically, where possible, compliance with conditions of rezoning.

PREVIOUS COMMENT 24: Provide a separate response letter explaining how rezoning conditions have been indentified and met based on the proposed Development Package Site Plan. Provide additional documents as needed to demonstrate compliance with rezoning conditions specific to building requirements.

Re-zoning condition 9 requires that exterior mechanical equipment be screened from view from the surrounding properties and streets. If any mechanical equipment is proposed on the new site and is visible from the surrounding properties and streets, a detail or detail drawings will have to be added to the plan detailing how the equipment will be screened. The screening must be architecturally compatible with the proposed development.

Re-zoning condition 10 requires incorporating one (1) or more visually appealing design treatments for screen walls adjacent to public streets. Per the plans, the south elevation (wall) of building one (1) will serve as the screening. Provide color renderings of building one to verify that compliance with this condition can be met.


If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.
04/24/2014 LAITH ALSHAMI ENGINEERING REVIEW Approv-Cond Laith Alshami, Engineering and Floodplain Review, 04/24/2014,

SUBJECT: Expansion of A-Family Self Storage
DP13-0230, T14S, R15E, SECTION 11

RECEIVED: Development Plan Package and Drainage Report on April 04, 2014

The Drainage Report is acceptable and it is hereby approved. The Development Package is recommended for conditional approval subject to revising the retention basin bleed pipe detail to show a cap at the pipe inlet with a two or three inch opening.

If you have any questions, I can be reached at 837-4933 or Laith.Alshami@tucsonaz.gov

RESUBMITTAL REQUIRED: Revised Development Plan Package
04/24/2014 LAITH ALSHAMI COT NON-DSD ENVIRONMENTAL SERVICES Reqs Change The Development Package has been reviewed and is denied. Please address the following on the resubmittal:
1. The size of the expansion of the site requires the full code compliance for the entire site. Therefore, the addition of a metal recycling container and enclosure is required in addition to the existing single refuse container enclosure. Please revise the plans to address previous comments 1-3.

2. Move the note regarding the anticipated method of collection and frequency from the detail on Sheet 4 to the general notes on the cover sheet.

If there are any questions, I can be reached at kperry@perryengineering.net
04/28/2014 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Approved 201 N. STONE AV, 1ST FL

TUCSON, AZ 85701-1207





MICHELENE NOWAK
ADDRESSING REVIEW

PH #: 721-9512



TO:
CITY PLANNING
FROM:
MICHELENE NOWAK, ADDRESSING REVIEW

SUBJECT:
DP13-0230 A-FAMILY SELF STORAGE EXPANSION/2ND REVIEW

DATE:
APRIL 28, 2014






The above referenced project has been reviewed by this Division for all matters pertaining to street naming/addressing, and we hereby approve this project.



1.) Submit a 24 x 36 Reverse Reading Double Matte Photo Mylar or bond paper of approved Development Plan to City Planning.



2.) All addresses will need to be displayed per Pima County Address Standards at the time of final inspection.



***The Pima County Addressing Section can use digital CAD drawing files and can be emailed to CADsubmittals@pima.gov

The digital CAD drawing files expedite the addressing and permitting processes when we are able to insert this digital data into the County’s Geographic Information System. Your support is greatly appreciated.***
04/29/2014 RONALD BROWN ZONING HC REVIEW Reqs Change 1. At detail 8/4 provide detectable warning strips at both ends of the marked crossing as per ICC A117.1, Sections 406.12, 13 and 14 as applicable.
END OF REVIEW
05/01/2014 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
05/02/2014 JOE LINVILLE LANDSCAPE REVIEW Approved
05/05/2014 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required.

Please resubmit the following items:

1) Two rolled sets of the plans
2) A disk containing all items submitted
3) All items requested by review staff
4) All items needed to approve this plan

Final Status

Task End Date Reviewer's Name Type of Review Description
05/05/2014 GERARDO BONILLA REJECT SHELF Completed