Permit Number: DP13-0228
Parcel: Unknown

Review Status: Active

Review Details: REVISION - - 1ST

Permit Number - DP13-0228
Review Name: REVISION - - 1ST
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
02/13/2015 ELIZABETH LEIBOLD ENGINEERING REVIEW Completed EOR was notified about standing stormwater issue at the spillway outlet area on the north portion of the project site. Any future standing stormwater that exceeds 24-hrs is subject to request for re-engineering of spillway to meet City of Tucson requirements for drain-down time (Tech Man Sec.4-03.3.5.1.3.b.) NW corner of site will need to be maintained to include adding erosion protection at west end of retaining wall at end of spillway. Also parcel owners shall be responsible to maintain restriction of vehicular access to area north of Culvers.
02/13/2015 ANDREW CONNOR LANDSCAPE REVIEW Completed
02/13/2015 STEVE SHIELDS ZONING REVIEW Completed

Final Status

Task End Date Reviewer's Name Type of Review Description
02/13/2015 CPIERCE1 APPROVAL SHELF RECEIVED