Permit Review Detail
Review Status: Completed
Review Details: DEV PKG - RESUBMITTAL
Permit Number - DP13-0217
Review Name: DEV PKG - RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/27/2014 | SPOWELL1 | START | PLANS SUBMITTED | Completed | |
| 05/27/2014 | ERIC NEWCOMB | ZONING HC | REVIEW | Approved | |
| 06/05/2014 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DP13-0217 1005 E Fort Lowell Road Development Package - Rezoning and DP Review for a New Parking Lot and Medical Service - Outpatient Use TRANSMITTAL DATE: June 06, 2014 DUE DATE: June 30, 2014 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code and Technical Standards and the Development Package 2-06 Standards were addressed. GENERAL COMMENT: Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 28, 2014. This development package has been reviewed concurrently with the rezoning case C9-13-12. Conditions of rezoning have not been established but will applicable and must be addressed on the development package. The rezoning case number will have to be listed in the lower right corner of all DP plan sheets. A general note that lists the case number, date of approval, and conditions of rezoning must be included on the cover sheet. Ensure that the next submittal of the development package demonstrates compliance with zoning comments related to the DS 2-06 and UDC requirements and all rezoning conditions. Follow-up comment: All freestanding and wall mounted light fixtures used in the Photometrics plans sheet shall be drawn and labeled on the Site Plan sheet 3. Zoning acknowledges receipt of the Photometric sheet with this current submittal. The plan sheet was presented to the PDSD Electrical Plans Reviewer LeeRay Hanly for his review for compliance with rezoning condition 13. The following is his response: To comply with the Outdoor Lighting Code they need to provide the following information in addition to the photometric plan already provided. All exterior lighting on the site, existing & proposed, must be included. 104.2.1 Lumen calculation on plans. There shall be documentation on the plans to demonstrate compliance with the lumen cap per Table 401.1, and which includes the following information: 1. Each exterior luminaire type with the lumens for that type, the quantity of each type and whether the luminaire is full cut-off or unshielded. 2. The total of full cut-off and unshielded lumens for the parcel. 3. A statement of the lighting area, the size of the permitted parcel, and the maximum allowed full cut-off and unshielded lumens. LeeRay City of Tucson Planning & Development Services 520-837-4906 office LeeRay is willing to review the requested information related to the Outdoor Lighting Code with an appointment. Zoning is also willing to review the final changes to the plans over the counter with an appointment. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents. |
| 06/13/2014 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Reqs Change | Comment not addressed; correct the label of the water main on sheet 4 of 14. The existing public water main located in the right-of-way south of the subject property is labeled as "EXISTING 8" PUBLIC VCP SEWER PER PLAN 1-73-16" |
| 06/16/2014 | ANDREW CONNOR | LANDSCAPE | REVIEW | Reqs Change | ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The landscape plan will contain the following Calculations Square footage of the site; Square footage of landscape areas coverage and calculation Square footage of the vehicular use area; number of parking spaces, including the required and provided parking space calculations; and the calculation of the required number of canopy trees Planting Plan Vegetation Plan and Schedules Both the proper and common name of existing plant materials Landscaping must be located entirely on site, except that, if approved by the City Engineer or designee, up to five feet of the required ten foot width may be placed within the adjacent right-of-way area or within the Major Streets and Routes (MS&R) right-of-way area on MS&R streets. Provide written permission for use of ROW and include any requested notes on landscape plan. Ensure that all Zoning comments and concerns are addressed. Additional comments may apply |
| 06/24/2014 | JOHN BEALL | COT NON-DSD | COMMUNITY PLANNING | Approved | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT COMMENTS Regarding SUBJECT: Community Design Review Committee Application CASE NUMBER: CASE NAME: DATE SENT DP13-0217 CODAC at Cobblestone - Ft. Lowell Road (X) Tentative Plat (X) Development Plan (X) Landscape Plan () Revised Plan/Plat () Board of Adjustment () Other - Elevations CROSS REFERENCE: C9-13-12 CODAC - Ft. Lowell NEIGHBORHOOD PLAN: Plan Tucson and Kino Area Plan GATEWAY/SCENIC ROUTE: NO COMMENTS DUE BY: June 24, 2014 SUBJECT DEVELOPMENT PLAN/PLAT HAS BEEN REVIEWED BY COMMUNITY PLANNING AND PRESERVATION, AND STAFF SUBMITS THE FOLLOWING COMMENTS: () No Annexation or Rezoning Conditions, Not an RCP - No Comment () Proposal Complies with Annexation or Rezoning Conditions () RCP Proposal Complies with Plan Policies () See Additional Comments Attached (X) No Additional Comments - Complies With Planning Comments Submitted on: 4/18/14 () Resubmittal Required: () Tentative Plat () Development Plan () Landscape Plan () Other REVIEWER: msp DATE: 06/24/14 |
| 06/25/2014 | PATRICIA GEHLEN | ZONING-DECISION LETTER | REVIEW | Reqs Change | The review of these plans have been completed and resubmittal is required. Please resubmit the following items: 1) Two rolled sets of the plans 2) All items requested by review staff 3) All items needed to approve the plans. |
| 06/25/2014 | PGEHLEN1 | COT NON-DSD | ENVIRONMENTAL SERVICES | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/02/2014 | CPIERCE1 | OUT TO CUSTOMER | Completed |