Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP13-0191
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2013 | DAVID RIVERA | ZONING | REVIEW | Reqs Change | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: David Rivera Principal Planner PROJECT: DP13-0191 5901 S Park Avenue Development Package - Multi-Family Development TRANSMITTAL DATE: October 7, 2013 DUE DATE: November 1, 2013 COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. The development Package has been reviewed with the understanding that the plat is to be approved by M & C and recorded. The review has been made but any approval of the development package cannot be granted by zoning until 30 days after the recordation of the Final Plat. --------------------------------------------------------------------------------------------------------------------------------------- This plan has been reviewed for compliance with the Development Package Standards listed in section 2-06 of the City of Tucson Administrative Manual. Also compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC). The review comments include the actual standard first with the applicable Administrative Manual section number and the following paragraph is the actual comment related to the specific item that must be addressed. If you need to review the sections listed below click on the link or copy it in the address bar of your internet program. http://www.amlegal.com/nxt/gateway.dll/Arizona/tucson_az_udc/administrativemanual?f=templates$fn=default.htm$3.0$vid=amlegal:tucson_udc_az This link will take you directly to the section used for the standards review. The UDC requirements are in the Unified Development Code and can be viewed at the same web link as above 1. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is . 2. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 2-06.1.0 GENERAL 2-06.2.0 APPLICATION SUBMITTAL REQUIREMENTS 2-06.3.0 FORMAT REQUIREMENTS 2-06.4.0 CONTENT REQUIREMENTS 2-06.1.0 GENERAL 2-06.1.1 PURPOSE This standard has been prepared for the purpose of informing applicants of the submittal and review requirements for development package documents to assure proper and adequate information is presented in a consistent manner, thereby providing the basis for an efficient and timely review. The development package documents are prepared in support of applications for building permits and related reviews. The information that is requested establishes the basis upon which the project will be approved and could affect what is required of the property in the future, should there be a proposal for expansion or for a different use of the property. This standard does not waive any applicable city regulations or codes. 2-06.1.2 APPICABILITY This standard shall be used for all site plans and tentative plats submitted to PDSD for review. 2-06.2.1 APPLICATION SUBMITTAL REQUIREMENTS Development Package applications are available from PDSD. Completed applications and accompanying materials shall be submitted to PDSD. Incomplete or inaccurate applications will not be accepted, nor will any application in which the pre-application conference or neighborhood meeting requirements have not been met. The types of documents and the specific number of copies required of each of the documents are on the PDSD website or may be obtained from PDSD. Resubmittals of development packages require a comment response letter that details how all previous comments have been addressed. Provide the same number of copies of the comment response letter as plans provided. The following documents and information shall be submitted upon application: 2-06.2.1 Application Form A completed application signed by the property owner or authorized designee; 2-06.2.2 Development Package A development package must be prepared to the format and content requirements described herein; 2-06.2.3 Related Reviews In addition to the plan process, a project may require review for other types of plans and documents. The applications for those processes are submitted to the appropriate department for review and approval. These related reviews can be applied for so that review can occur concurrently with the development package application. However, it must be understood that, should the related application be approved subject to conditions or denied, this may affect the; 2-06.2.4 Concurrent Reviews The development package is designed to allow for concurrent review of any site related reviews. Concurrent review means that all plans and documents needed for the review are submitted as one package. Examples of site related reviews include but are not limited to: site plans, landscape plans, NPPO plans, water harvesting plans, grading plans, SWPPP plans, floodplain use permits, and overlay reviews. Separate applications are often required for the different site related reviews even if the plans are submitted concurrently; and, 2-06.2.5 Fees Fees in accordance with Section 4-01.0.0, Development Review Fee Schedule. 2-06.3.0 FORMAT REQUIREMENTS 2-06.3.1 - Each sheet shall measure 24 inches by 36 inches and include a minimum one inch margin on left side and one-half inch margin on all other sides to facilitate efficient record keeping. A larger sheet format may be used with the approval of the Planning and Development Services Department (PDSD). 2-06.3.2 - All mapped data shall be drawn at an engineering scale having no more than 50 feet to the inch. This scale is the minimum accepted to assure the plan will be legible during review and when digitized and/or reduced for record-keeping purposes. The same scale shall be used for all sheets within the set. Smaller scales (60:1 or greater) may be used for some or all of the sheets with the prior approval of PDSD when it is determined legibility and the ability to be digitized and/or reduced for archiving will not be affected. 2-06.3.3 - All lettering and text (upper or lower case), and numbering, shall be a minimum of three-thirty-seconds inches in height to assure the plan will be legible during review and when digitized and/or reduced for archiving. 2-06.3.5 - A three-inch by five-inch space shall be reserved in the lower right quadrant of each sheet for an approval stamp. 1. - COMMENT: All plan sheets including landscape, NPPO and Irrigation sheets in the development package (with exception to the reference Final Plat sheets) must be provided with the approval stamp 2-06.3.6 - Provide a blank three-inch by five-inch block in the lower right corner of the plan adjacent to the title block on the first sheet of the development package for use by Pima County Addressing. 2. - COMMENT: Provide the requested block on the cover sheet only. 2-06.3.8 - The north arrow, contour interval, and scale as applicable to each sheet should be placed together in the upper right corner of each sheet. 3. - COMMENT: List the contour interval under the north arrow on the applicable DP sheets. 2-06.3.9 - The plan drawing shall be oriented with north toward the top of the sheet. If it is not practical to orient north to the top of the sheet, the plan drawing shall be oriented with north to the left side of the sheet. 4. COMMENT: Revise the direction of the drawing to comply with this standard as noted above. 2-06.3.12 - An index of sheets in the development package shall be provided on the first sheet. 5. - COMMENT: Provide the sheet index on the cover sheet of the development package. 2-06.4.0 CONTENT REQUIREMENTS 2-06.4.2 - The title block shall include the following information and be provided on each sheet: 6. - COMMENT: Include the information in the Title Block as required by the following standards. 2-06.4.2.B - A brief legal description and a statement as to whether the project is a resubdivision are to be provided. On resubdivisions, provide the recording information of the existing subdivision plat; 7. - COMMENT: Provide in the title block of all plan sheets, a brief legal description of the property. If the property is part of a recorded plat, list the lot number(s) and map and plat recording information. The legal description should match the legal description listed in the final plat (Alvord Court Housing Lot one and include the recording sequence number). 2-06.4.2.D - The page number and the total number of pages in the package (i.e., sheet xx of xx). 8. - COMMENT: List the page numbers as required by the standard as noted above. All sheets except the final plat sheet should be numbered. The drawing index list should also include the specific sheet numbers as listed in the title block. 2-06.4.3 - The administrative street address and relevant case numbers (development package document, subdivision, rezoning, board of adjustment, DDO, MDR, DSMR, overlay, etc.) shall be provided adjacent to the title block on each sheet. 9. - COMMENT: This project has been assigned the Development Package case number DP13-0191 list the case number in the lower right corner of all plan sheets. A final plat is related to this project. Include in the lower right corner of all plan sheets, the case number for the final plat. If any other case number is associated with this project list the PDSD assigned case numbers in the lower right corner of all plan sheets. 2-06.4.4 - The project-location map to be located on the first sheet of the development package in the upper right corner, shall cover approximately one square mile, be drawn at a minimum scale of three inch equals one mile, and provide the following information. 10. - COMMENT: Include on the following information on the location map 2-06.4.2.B - Identify major streets and regional watercourses within the square mile area and all streets that abut the subject property; and, 11. - COMMENT: Label Airport Wash and Bilby Road on the location map. 2-06.4.2.C - Section, township, and range; section corners; north arrow; and the scale will be labeled. 12. - COMMENT: Label the section corners adjacent to the corners of Section seven (7). 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 2-06.4.7.A.6 - If a plan or plat is prepared in conjunction with other applications or overlays or the parcel being developed is subject to conditions of an application processed previously, additional information must be added to the plan. Such applications and overlays include, but are not limited to: annexations; rezonings; special exceptions; Board of Adjustment variances; Design Development Options; Technical Standard Modification Request; overlays (Airport Environs Zone, Environmental Resource Zone, Gateway Corridor Zone, Hillside Development Zone, Historic Preservation Zone, Major Streets and Routes, Rio Nuevo District, Scenic Corridor Zone, WASH); Modification of Development Regulations through the Downtown Area Infill Incentive District or Rio Nuevo District; Downtown Heritage Incentive Zone; or, Design Review Board. Provide the following information on the plan. 13. - COMMENT: Add as a general note that this development has been designed to comply with the regulations of the Major Street and Routes Overlay. 2-06.4.7.A.8 - For development package documents provide: 14. - COMMENT: Add the following information as required by the following standards. 2-06.4.7.A.8.a - Floor area for each building; 15. - COMMENT: Under the site information text block, list the floor area of each unit and include the overall GFA. If only two models are proposed and the square footage is the same list the square footage of each model and add the total square footage for all units, i.e. model and model 2. Also clarify if the smaller building is a recreational center or building that is to be utilized by the tenants only. Label the use of the building and square footage and height. Include any labels such as pool areas etc. 2-06.4.7.B - Drainage Notes List the following notes as appropriate: 16. - COMMENT: Add the following notes as required by the following standards. 2-06.4.7.B.1 - List the following notes on all plans/plats: "The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall." 17. - COMMENT: Add above note on the site plan sheet as a general note. 2-06.4.7.B.3 - List the following note on all development package documents: "Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan." COMMENT: 2-06.4.7.C - Streets and Roads Notes 18. - COMMENT: Add the following notes as required by the following standards. 2-06.4.7.C.2 - List the following note on all development package documents: "No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual." 19. - COMMENT: Add above note on the site plan sheet as a general note. 2-06.4.7.C.3 - Provided the following notes as applicable: 2-06.4.7.D - Utilities Note All development package documents are to include the following note: "Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public." 20. - COMMENT: Add above note on the site plan sheet as a general note. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 21. - COMMENT: Add the following notes as required by the following standards. 2-06.4.8.A - Provide site boundary/subdivision perimeter information, including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system. 22. - COMMENT: Label the distance and bearings on site plan sheet as has been labeled on the final plat. 2-06.4.8.C - The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 23. - COMMENT: Add to the site and civil sheets the information as noted above by this standard. See additional comments by the engineering reviewer related to this standard as noted above. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 24. - COMMENT: Add the following notes as required by the following standards. 2-06.4.9.B - Identify each block or lot by number within the subdivision boundary and include the approximate square footage of each, or a note may be provided stating that all lots comply with the minimum lot size requirements. 25. - COMMENT: Label the newly recorded lot number / name of the lot on the site plan sheet. 2-06.4.9.F - All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. If the property is being rezoned, use those boundaries and classifications. The basis for this requirement is that some zoning requirements on a project are based on the zoning classification of adjacent property. Also, in some instances, each zone has to be taken into consideration on property that is split by two or more zoning classifications, as each may have different requirements. 26. - COMMENT: Label on the site plan sheet the zoning classification adjacent to site boundary of the subject property 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. 26A. - COMMENT: The zoning setbacks adjacent to the east and south are based on the adjacent zoning classifications. The building setbacks adjacent to both are based on the greatest of 10 feet or 3/4 the height of the wall adjacent to the property boundary. Zoning could not verify the required building setbacks building setbacks without actual wall heights adjacent to the east and south property lines. Label the wall heights and the proposed and required building setbacks. Additional comments may be forthcoming based on the response to this comment and revisions to the plans. If the building setbacks do not meet the minimum requirements, a separate review and approval through the Design Development Option (DDO) process will be required. Zoning cannot do a final approval of the DP until the DDO is approved. Ensure that the overall building setback(s) from all property lines that abut this project site have been labeled on the site plan sheet. 2-06.4.9.H - Proposed Traffic Circulation 2-06.4.9.H.5.a - Show all motor vehicle off-street parking spaces provided, fully dimensioned. As a note, provide calculations on the number of spaces required (include the ratio used) and the number provided, including the number of spaces required and provided for the physically disabled. The drawing should indicate parking space locations for the physically disabled. A typical parking space detail shall be provided for both standard parking spaces and those for the physically disabled. For information on parking requirements for the physically disabled, refer to adopted building and accessibility codes of the City of Tucson. Design criteria for parking spaces and access are located in Section 7.4.6, Motor Vehicle Use Area Design Criteria, of the UDC. 27. - COMMENT: Provide a typical parking space detail drawing for the standard parking spaces. Label the drop off zone on the site and civil plan sheets. 2-06.4.9.H.5.d - Show bicycle parking facilities fully dimensioned. For specifics, refer to Section 7.4.9, Bicycle Parking Design Criteria, of the UDC. Provide, as a note, calculations for short and long term bicycle spaces required and provided. 28. - COMMENT: Revise the bicycle parking calculations to correctly list the number of spaces required for both the short and long term. Per the number of bedrooms listed in the site information text block on sheet two (2) there should be a minimum of 17 long term spaces. (total 33 bedrooms x .5 equals 16.5 spaces required rounded up to 17 required) Revise C102, keynote 0.21 to state "short term" Demonstrate on the site and civil plan sheets the location of the long term bicycle parking facilities. Include a dimensioned detail drawing for the long term bicycle parking facilities. Revise bicycle parking calculation for the long term facilities. 2-06.4.9.I - Show all right-of-way dedications on or abutting the site and label. If the development package documents have been prepared in conjunction with a subdivision plat or is required as a condition of approval of a review process, such as a rezoning, street dedications in accordance with the Major Streets and Routes (MS&R) Plan may be required by these processes. Projects bounded by streets having only a portion of the right-of-way width dedicated will be required to dedicate right-of-way, up to one-half, to complete the street width. Should there be any proposed street or alley vacation, provide this information. If vacation has occurred, include the recording information. 29. - COMMENT: Label the dedication of right of way for Park Avenue as depicted on the final plat. Include the recordation information. 2-06.4.9.K - Identify and provide dimensions, approximate areas in square footage, and purposes of any lots proposed for dedication (such as open spaces, recreation areas, or natural areas) or for reservation for a public use (such as public parks, water facilities, or school sites). 30. - COMMENT: Identify on the site and civil plan sheets 2-06.4.9.M - Grading Plan 2-06.4.9.M.2 - Concurrent Review. For all projects, grading plans may be included in the development package and will be reviewed concurrently. 31. - COMMENT: The grading plan is reviewed concurrently with the site plan. Once the site plan is approved as it relates to the zoning review purview the grading plan is also considered approved. However any changes that need to be made on the site plan sheet must be made on all corresponding sheets to ensure consistency. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 32. - COMMENT: As noted above in a separate comment, label the overall square footage and height of the buildings on the footprint of the site and civil plan sheets. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 33. - COMMENT: All sidewalks must be a minimum of four (4) feet in width. A portion of the sidewalk next the southeast corner of the smaller building is labeled as three (3) feet. Revise the drawing and label the sidewalk to indicate a four (4) wide sidewalk at the noted location. 2-06.4.9.V - For gang mailboxes indicate location to assure there are no conflicts with other requirements, such as pedestrian accessibility, utilities, and landscaping. 34. - COMMENT: Identify the location of gang mailboxes if applicable to this project. Otherwise identify the type and location of mailboxes proposed for this development. 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Indicate if there are any existing billboards on site. Compliance to the Sign Code, Chapter 3 of the Tucson Code, is required. 35. - COMMENT: If applicable indicate the location of any freestanding monument signs. Include the size and type. 2-06.4.9.X - Show compliance with landscaping and screening requirements by locations, material descriptions, and dimensions. Specific plant or hardscape material shall be detailed on a landscape plan. A detailed landscape plan is required. In accordance with Section 2-11.0.0, Landscape Plan Requirements. 36. - COMMENT: See the landscape reviewer comments related to the requirements for landscape buffers and screening. If you have any questions about this transmittal, please call David Rivera, (520) 791-5608. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package site plan and any requested documents. |
| 10/07/2013 | RBROWN1 | ADA | REVIEW | Passed | |
| 10/10/2013 | MARTIN BROWN | FIRE | REVIEW | Denied | Please indicate location(s) of existing and/or proposed fire hydrants. Refer to Section 507.5 of the 2012 International Fire Code for spacing requirements. |
| 10/28/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 10/28/2013 | RONALD BROWN | H/C SITE | REVIEW | Denied | SHEET C100 AND ALL OTHER SITE PLANS 1. Delete the detectable warning strips at the passenger drop off zone and the accessible parking aisle. These are safe zones and do not require detectable warnings. 2. Redesign the passenger loading zone to be an accessible passenger loading zone as required by the 2012 IBC, section 1107.7 and 2009 ICC A117.1, Section 503. 3. Show directional slope arrows at all ramps and 1:12 slope maximum slope. 4. Provide a note indicating compliance with the 2009 ICC A117.1, Section 403.3 Maximum accessible route slopes of 5% max running slope and 2% max cross slopes. 5. Provide a large scale detail of all different types of marked crossings showing all accessible requirements such as dimensions, slopes, markings, ramps and detectable warning strips. SHEET C200 6. At detail 16/C200: a. Delete the detectable warning strips. b. Reference comments on sheet C100. 7. At detail 1/C200: a. Delete the detectable warning strips. b. Change the dimensions to 8', 8' and 9'. The 8' wide accessible parking space is to be a Van Accessible parking space. END OF REVIEW |
| 10/30/2013 | ANDREW CONNOR | LANDSCAPE | REVIEW | Denied | ADMINISTRATIVE MANUAL SECTION 2-10.0.0: LANDSCAPE PLAN REQUIREMENTS Identification and Descriptive Data All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. The landscape plan will contain the following identification in the lower right corner of each sheet: Any relevant case number for reviews or modifications that affect the site Square footage of the oasis allowance area and calculation Interior landscape borders are required as a buffer and visual transition along the common property lines between adjacent land uses and zones as determined in Table 7.6.4-1. Interior landscape border is required to screen this site from adjacent residential zoned properties. One canopy tree is required for every 33 linear feet of landscape border or fraction thereof, excluding vehicular ingress or egress points. Where motor vehicle parking spaces or parking area access lanes (PAALs) are located next to the property line or where the interior landscape border conflicts with a utility easement, an interior landscape border is not be required if all of the following requirements are met: (1) An equivalent number of trees are planted elsewhere on the site between the building(s) and the property line, or if the use on the site does not include buildings, the required canopy trees are located between the principal use and the property line; (2) The trees are evenly distributed over the site; and (3)The minimum planting area required in Section 7.6.4.B.3, Planter Area, is provided for each canopy tree . Revise the NPP inventory summary Sheet NP1 to reflect the correct species inventoried Ensure that all Zoning and Engineering comments and concerns are addressed. Additional comments may apply. |
| 10/30/2013 | ANDREW CONNOR | NPPO | REVIEW | Reqs Change | Revise the NPP inventory summary Sheet NP1 to reflect the correct species inventoried |
| 11/01/2013 | ELIZABETH EBERBACH | ENGINEERING | REVIEW | Denied | TO: Bill Schlesinger, P.E., Ryan Stucki, P.E. SUBJECT: DP13-0191 Alvord Apartments Grading Development Package 1st submittal Engineering Review ADDRESS: 5901 S PARK AV, Ward 5 LOCATION: T15S R14E Section 7 FLOODPLAIN: FEMA zone X-unshaded, 2289 L WATERSHED: Airport Wash Watershed AW (balanced basin management area) REVIEWER: Elizabeth Leibold, P.E. SUMMARY: Engineering has reviewed and provided grading comments to the Development Package sheets for the Alvord Apartments project. Engineering does not recommend approval at this time. Prior to resubmittal, address the following comments. MASTER COVER SHEETS/ GENERAL NOTES/GRADING/SITE SHEETS COMMENTS: 1) Admin Man Sec.2-06.4.9.M, Tech Man Sec.2-01.4.F.b: Address the following grading comments: a) Add spot elevations for sidewalk to show 2% max cross slope and less than 5% longitudinal slopes. b) Label vertical benchmark and basis of horizontal bearing on planview. c) Label spot elevations & grade within all waterharvesting / detention / retention basins showing positive gradient and labeled cover material (sediment/erosion control). d) Provide cross sections at all sides of buildings showing basins, to show existing grade and proposed grades, swales, WSEL's, and FFE. 2) Tucson Code Chapter 26, Article II: SWPP comments: a) Dimension width of construction entrance of SWPPP exhibit. b) Add construction entrance to southwest entrance. c) Identify and add receiving waters to location map and as a general SWPPP note. 3) Admin Man Secs.4.9.I, 2-06.4.8.C, 4.9.H.4, Tech Man Sec.10-01.5.1.A: On Site Plan sheet A000, address the following comments: a) Label existing ROW along Park Avenue per recorded, approved final plat. b) Label existing sidewalk and proposed sidewalk along frontage streets. c) Show existing SVT's on site plan and label dimensions for both future and existing SVT's on planview. 4) Admin Man Sec.4.9.O, Tech Man Sec.2-01.9: Address the following setback comments: a) Due to high failure rate of basins to meet drain down time requirements, all retention areas (basin and water harvesting) shall have positive gradients. Add bleed pipe systems, scuppers, positive gradients, and sufficient outlet areas to meet drain down time, and to prevent hold-up, delays at post-construction final grading inspection approval stage. b) Provide geotechnical report recommendations for basin setbacks form structures, or provide 20-ft setback from buildings to basins. c) Regarding proposed vegetation, provide soils/geotechnical report showing that vegetation meets soils report recommendations, or, provide positive gradient away from structures with setback for irrigation and proposed vegetation per building codes. 5) UDC 8.4.3.B.6, Admin Man Sec.2-06.4.9.N.4: Drainage Report needs to meet minimum standards per City Drainage Manual and Detention Retention Manual. Address the following comments: a) Admin Man Sec.4.9.N.1: Explain in drainage report how FFE's were determined - provide adjacent 100-year WSEL and corresponding finished floor elevation on planview grading/drainage sheet C102 and in report. b) Tech Manual Secs.4-04, 4-03: Any proposed depressed areas must follow geotech/soils report recommendations. Positive gradients should be provided away from structures per building codes. Swales and/or bleed pipes and/or storm drain system should be provided to provide positive gradient from basins. c) Volume for basins may be used within waterharvesting areas. Explain volume of detention/retention is each basin location in report. Retention areas also may use bleed pipes to meet the maximum 12 hour drain down time. d) See Technical Manual Section 4-04.2.1.1 for report format and content requirements. e) Geotechnical infiltration testing may be used to substantiate basin location however safety factors must be used and the basins must have post construction infiltration testing if bleed pipes are not used. Basins without positive gradients to outlet infrastructure are not recommended due to high failure rates and significant additional cost and time to developer if basins fail and re-engineering of basins, resubmittal of the revision for review and approval and re-construction, are required prior to final inspection approval. 6) Tech Man Sec 8-01.5: Add detail showing 10-ft clear between bollards and gate for solid waste pick-up area. Label gate material - this material must be opaque. Also show 2% grades away from pad; this area may not be used for any flow line for drainage. Submit revised sheets, any supporting documentation, and comprehensive response letter. Please call me to set up a meeting prior to resubmittal to discuss comments, or call for clarifications at 837-4934. Elizabeth Leibold, P.E., CPM, CFM Civil Engineer Engineering Division Planning & Development Services Department |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/05/2013 | CPIERCE1 | REJECT SHELF | Completed |