Permit Number: DP13-0104
Parcel: 13731373A

Review Status: Completed

Review Details: DEV PKG

Permit Number - DP13-0104
Review Name: DEV PKG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2013 PGEHLEN1 START PLANS SUBMITTED Completed
06/07/2013 TIM ROWE PIMA COUNTY WASTEWATER Passed
06/07/2013 JENNIFER STEPHENS PIMA COUNTY ADDRESSING Passed Per Addressing form
06/10/2013 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved See letter in SIRE. Comments are informational.
06/10/2013 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved See letter in SIRE
06/10/2013 PGEHLEN1 COT NON-DSD ENVIRONMENTAL SERVICES Denied Project is not approved. Approach to waste enclosure requires 14'x40' clear space. In addition, Recycle storage and service is not addressed.



Jeff Drumm, P.E.
Environmental Manager
City of Tucson Environmental Services
520-837-3713
06/10/2013 RONALD BROWN ADA REVIEW Passed
06/11/2013 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
06/12/2013 CSCHULT1 COT NON-DSD FIRE Denied Please indicate existing fire hydrant location(s), with dimensions to buildings and/or property lines. Refer to the 2012 International Fire Code Section 507 for requirements.
Per your plan on page 2 shows hydrant over 400' will need fire hydrant(s) with 400' feet of all parts of building.

Plans indicate existence of security gate(s). Refer to City of Tucson amendments to the 2012 International Fire Code (Sections 503.6, 503.6.1 and 503.7) for requirements. Indicate methods of compliance on plans.
06/17/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Midvale Auto Spa
Development Package (1st Review)
DP13-0104

TRANSMITTAL DATE: June 17, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Unified Development Code (UDC), Administrative Manual (AM) & Technical Standards Manual (TSM) were addressed.

1. This site was reviewed for full code compliance for the entire site.

The following comments are based on the requirements of Administrative Manual (AM) 2-06.0.

2. A.M. 2-06.4.2.B Provide a brief legal description within the title block.

3. A.M. 2-06.4.3 Provide the following relevant case numbers on the plan adjacent to the title block on all sheets, DP13-0104 and C9-12-14.

4. A.M. 2-06.4.7.A.3 Revise General Note1 to include "PROPOSED ZONING IS C-2".

5. A.M. 2-06.4.7.A.4 General Note 2 should list the proposed use as "AUTOMOTIVE; MINOR SERVICE AND REPAIR - AUTOMOTIVE WASHING - SELF SERVICE SUBJECT TO USE SPECIFIC STANDARDS 4.9.13.E."

6. A.M. 2-06.4.8.C The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

7. A.M. 2-06.4.9.E There is a heavy line shown south of the proposed development. It appears that a lot split is proposed. Clarify what this line is. If a new lot is proposed a minor subdivision will be required.

8. A.M. 2-06.4.9.F All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. That said provide the zoning for the parcels on the north side of Irvington and west side of Midvale Park.

9. A.M. 2-06.4.9.H There appears to be access provided to the undeveloped area to the south Per UDC Section 7.4.6.H.1 Barriers, such as post barricades or wheel stop curbing, are required in a vehicular use area to prevent vehicles from extending beyond the property lines, to prevent cars from damaging adjacent landscaping, walls, or buildings, overhanging adjacent sidewalk areas, and/or driving onto unimproved portions of the site. Show the required barrier on the plan.

10. A.M. 2-06.4.9.H Per UDC Section 7.4.6.E.2 The minimum height clearance along access lanes and PAALs is 15 feet. That said provide the clearance dimension for the proposed "CANOPY" shown on the plan.

11. A.M. 2-06.4.9.H.a The provided vehicle parking space calculation is not correct. Per UDC Table 7.4.4-1 COMMERCIAL SERVICES USE GROUP, Automotive Washing Self-Service zero (0) vehicle parking spaces required. Revise the vehicle parking space calculation. Also per Rezoning Condition 21 "THERE SHALL BE NO MORE THAN 2 VEHICLE-PARKING SPACES FRO THE PORPOSED USE".

12. A.M. 2-06.4.9.H.a Per the Preliminary Development Plan (Revised) dated 11-26-12 the four (4) vehicle parking spaces shown in the northwest corner where depicted as "VACUUM BAYS". Clarify what these spaces are for. Per Rezoning Condition 21 "THERE SHALL BE NO MORE THAN 2 VEHICLE-PARKING SPACES FRO THE PORPOSED USE".

13. A.M. 2-06.4.9.O Provide the street perimeter yard setback dimension from the proposed "VACUUM EQUIP BLDG" to the back of future curb along Midvale Park.

14. A.M. 2-06.4.9.Q Provide the height of the proposed canopy within the footprint on the plan.

15. A.M. 2-06.4.9.R Provide a width dimension for all proposed sidewalks shown on the plan.

16. A.M. 2-06.4.9.R Per TSM 7-01.4.1.B A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located and TSM 7-01.4.3.A All sidewalks must be a minimum of four (4) feet wide and installed to avoid any obstruction which decreases the minimum width to less than four (4) feet. That said demonstrate on the plan how these requirements are met for the east and west side of the main building.

17. A.M. 2-06.4.9.U The requirements of Rezoning Condition 15 have not been fully met. Provide four-sided elevations for all structures, canopies and vacuum buildings, with the next submittal.

18. A.M. 2-06.4.9.U Rezoning Condition 16 requires cross access with the residual portion of the parcel to the south. If the residual portion of the parcel to the south is to be split off and used as an individual parcel, see comment 7, a recorded cross access agreement will be required.

19. A.M. 2-06.4.9.U It does not appear that the requirements of Rezoning Condition 21 are met.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

Sshield1 on DS1/planning/New Development Package/ DP13-0104

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and recorded cross access agreement if required.
06/19/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Approved 4350 E. Irvington Road
Post Office Box 711, Tucson, AZ 85702


WR#264679 June 19, 2013

JAS Engineering
P.O. Box 1888
Tucson, Arizona 85702

Dear JAS Engineering:

SUBJECT: Midvale Auto Spa
DP13-0104

Tucson Electric Power Company has reviewed and approved the development plan submitted June 7, 2013. It appears that there are no conflicts with the existing facilities within the boundaries of this proposed development.

Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer.

In order to apply for electric service, call the New Construction Department at (520) 918-8300. Submit a final set of plans including approved site, electrical load, paving off-site improvements and irrigation plans, if available include a CD with the AutoCAD version of the plans.

If easements are required, they will be secured by separate instrument. Your final plans should be sent to:
Tucson Electric Power Company
Attn: Mr. Richard Harrington
New Business Project Manager
P. O. Box 711 (DB-101)
Tucson, AZ 85702
520-917-8726

Should you have any technical questions, please call the area Deisgner, Jeniffer Necas at (520) 918-8295.

Sincerely,


Elizabeth Miranda
Office Support Specialist
Design/Build
Enclosures
cc: DSD_CDRC@tucsonaz.gov, City of Tucson (email)
J. Necas, Tucson Electric Power
06/21/2013 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved Regional Traffic Engineering has no comments on this submittal and recommends its acceptance. Thank you.

________________________________
06/21/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
06/25/2013 RONALD BROWN ZONING HC REVIEW Denied SHEET 2
1. At the most Northerly marked crossing leading to Irvington Road:
a. The crossing would be shorter and more safe if the crossing angle were more perpendicular to the PAAL and flow of traffic.
b. At the south end of the marked crossing, provide a curb ramp as per 2009 ICC A117.1, Section 406.7 including flared sides.
c. At the North end of the marked crossing, provide a sidewalk ramp as per 2009 ICC A117.1, Section 405.7 including required landing space.
d. Provide dimensions for all accessible elements of the marked crossing.
2. At the most Southerly marked crossing leading to Midvale Park Road:
a. At the most westerly end of the marked crossing, provide a sidewalk ramp as per 2009 ICC A117.1, Section 405.7 including required landing space.
3. Insure all accessible slopes comply with the 2009 ICC A117.1, Section 502.5, 5% maximum running slope and 2% maximum cross slopes.
4. Show dimensional widths of all accessible routes and marked crossings.
SHEET 4
5. At detail 2, show grade slopes to be in compliance with ICC A117.1, Section 502.5, 2% maximum in all directions.
END OF REVIEW
06/26/2013 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Here are my comments -

DATE: 6/25/2013
CASE: DP13-0104 MIDVALE AUTO SPA
COMMENT: No objections or adverse comments

Daily PM Peak
Vehicle Trip Generation: 0 78

Thanks,
-Eric

Additional notes:

See Additional documents in SIRE
07/01/2013 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved Site plan approved. Contact City of Tucson Egineering permits and codes 791-5100 for any work performend in the right of way.
07/02/2013 LOREN MAKUS ENGINEERING REVIEW Denied Information on different sheets of the plan doesn't match. Please perform quality assurance on all sheets and re-submit. Additional comments may be forthcoming.
1.
The retention basin WSEL on the development plan is above the top of the basin. Show extent of ponding for the basin. Show contours for adjacent properties to demonstrate ponding will not extend beyond the property lines.

Add a note that signage is by separate review and permitting.

Drainage Report
Revise page 3 to address conditions at this site. Ensure that all parts of the report are updated as necessary.


SWPPP
Provide a copy of the current construction general permit in the SWPPP. Make sure the SWPPP meets the requirements of the current general permit
07/08/2013 GLENN HICKS COT NON-DSD PARKS & RECREATION Approved
07/08/2013 JOE LINVILLE LANDSCAPE REVIEW Denied A vehicular use area must be provided with post barricades or wheel stop curbing designed to prevent parked vehicles from extending beyond the property lines; damaging adjacent landscaping, walls, or buildings and to prevent vehicles from driving onto unimproved portions of the site.
per DS 3-05.2.3.C.
Revise the plans as necessary.

Add the CDRC case number and any related case numbers to the landscape and native plant preservation plans. DS 2-07.2.1.B

All disturbed, grubbed, graded, or bladed areas not otherwise improved shall be landscaped, reseeded, or treated with an inorganic or organic ground cover to help reduce dust pollution. Revise landscape plan to include dust control for the future development area. LUC 3.7.2.7. DS 2-06.5.2.C

Trees and shrubs are to be selected and located so that, at maturity, they do not interfere with existing on-site or off-site utility service lines or utility or other easements.

Revise the landscape/NPP plans to show the limits of grading. DS 2-07.2.2.B.5

Show and identify (by species) existing plants to remain in place on the landscape plan. DS 2-07.2.2.A.1.e

Vegetation or structures higher than thirty (30) inches must be located outside of the sight visibility triangle

Submit a native plant preservation plan. LUC 3.8.4.2

Revise the landscape plan to provide a continuous tree canopy per the conditions of rezoning.

Revise the page titles for accuracy.

Revise the note regarding the total shrubs and groundcovers on sheet 6 located below the plant schedule. It appears to be incorrect.
07/09/2013 ED ABRIGO PIMA COUNTY ASSESSOR Passed
07/09/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change This review has been completed and resubmittal is required.

Please resubmit the following items:

1) Two rolled sets of the plans
2) One disk containing all items submitted
3) All items requested by review staff
4) All items needed to approve these plans.
07/09/2013 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
07/09/2013 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
07/09/2013 PGEHLEN1 COT NON-DSD TUCSON POLICE DEPARTMENT Approved I have no issues with this request.

CSO Becky Noel #37968
Tucson Police Dept
837-7428
07/09/2013 PGEHLEN1 OTHER AGENCIES U. S. POST OFFICE Passed
07/09/2013 PGEHLEN1 UTILITIES CENTURYLINK Passed
07/09/2013 PGEHLEN1 UTILITIES EL PASO NATURAL GAS Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/15/2013 CPIERCE1 OUT TO CUSTOMER Completed