Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: DP13-0006
Parcel: 138240860

Review Status: Completed

Review Details: TENTATIVE PLAT REVIEW

Permit Number - DP13-0006
Review Name: TENTATIVE PLAT REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/25/2013 PGEHLEN1 START PLANS SUBMITTED Completed
01/25/2013 PGEHLEN1 PIMA COUNTY WASTEWATER Passed Per discussion with Chad from WWM
01/25/2013 PGEHLEN1 PIMA COUNTY ADDRESSING Passed Per Addressing form
01/28/2013 ZELIN CANCHOLA COT NON-DSD TRAFFIC Approved
01/28/2013 RONALD BROWN ADA REVIEW Passed
01/29/2013 PGEHLEN1 ENV SVCS REVIEW Approved Environmental Services approves the Tenative Plat pg 2of2 for waste and recycle enclosure footprint.



Jeff Drumm, P.E.
Environmental Manager
City of Tucson Environmental Services
520-837-3713
01/29/2013 STEVE SHIELDS ZONING REVIEW Denied CDRC TRANSMITTAL

TO: Planning and Development Services Department
Plans Coordination Office

FROM: Steve Shields
Lead Planner

PROJECT: Cope Community Services - 1525 W. Commerce Ct.
Development Package (1st Review)
DP13-0006

TRANSMITTAL DATE: January 30, 2013

DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Section 4.1.7.1, LUC, permits a maximum of one year from the date of application to obtain approval of a tentative plat. If, at the end of that time, the tentative plat has not been approved, it must be revised to be in compliance with all regulations in effect at that time, and must be resubmitted for a full CDRC review. The one-year expiration date for this tentative plat is January 23, 2014.

2. This review is full code for the areas of change only, i.e. new proposed lot lines, no floor area expansion proposed.

The following comments are based on the COT Land Use Code and Development Standards:

1. D.S. 2-01.3.3 Provide the development package number, DP13-0006 adjacent to the title block on each sheet.

2. D.S. 2-01.3.3 Provide any relevant case numbers, MDR, adjacent to the title block on each sheet.

3. D.S. 2-01.3.7.A.4 Revise "GENERAL NOTE 4" to include the subject to section "3.5.4.8.B" for the medical services outpatient use.

4. D.S. 2-01.3.7.A.7 Provide the annexation number "C9-83-34" adjacent to the title block on each sheet.

5. D.S. 2-01.3.7.A.8 Provide the subdivision plat number S13-002 adjacent to the title block on each sheet.

6. D.S. 2-01.3.7.A.9.a As a general note provide the floor area for each building.

7. D.S. 2-01.3.9.H.5.a The gross floor area (GFA) listed for lots 1, 3 & 4 in the vehicle parking space calculation, sheet 1, do not match the GFA listed within the building footprint on sheet 2.

8. D.S. 2-01.3.9.H.5.c The loading space calculation shows four (4) provided but there are only two shown on the plan.

9. D.S. 2-01.3.9.O Based on the most recent aerial photos and the last approved building and site plans there is a canopy that runs connects the buildings shown on lots 1 & 4. Cleary show the canopy on the plan. For zoning requirements no perimeter yard is required between lots 1 & 4 but building/fire code may require a setback. Contact COT structural and fire review for the building code setback.

10. D.S. 2-01.3.9.O There are numerous other canopies not shown on the plan. Cleary show all canopies on the plan as they my have an effect on building/fire code requirements.

11. Zoning acknowledges that cross access & cross parking is to be provided per recorded covenants, conditions and restrictions (CC&Rs). That said provide a copy of the recorded CC&Rs and provide the recordation information on the plan.

If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.gov

Sshield1 on DS1/planning/New Development Package/ DP13-0006

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package.
01/30/2013 MARTIN BROWN COT NON-DSD FIRE Denied denied based on the fact that the buildings are connected with and this is not shown on the plans. Please update plans to show what is on the site.
01/31/2013 TOM MARTINEZ OTHER AGENCIES AZ DEPT TRANSPORTATION Approved The proposed development will not impact any ADOT facilities and recommends its acceptance. Thank you.

________________________________

Confidentiality and Nondisclosure Notice: This email transmission and any attachments are intended for use by the person(s)/entity(ies) named above and may contain confidential/privileged information. Any unauthorized use, disclosure or distribution is strictly prohibited. If you are not the intended recipient, please contact the sender by email, and delete or destroy all copies plus attachments.
.
02/11/2013 JASON GREEN ENGINEERING REVIEW Denied DATE: February 15, 2013
SUBJECT: COPE Community Services Development Plan Package- Engineering Review
TO: Cypress Civil Development, Attn: Kevin Hall, PE
LOCATION: 1525 W Commerce Court; T15S R13E Sec15
REVIEWERS: Jason Green, CFM
ACTIVITY: DP13-0006

SUMMARY: Engineering Division of Planning & Development Services Department has received and reviewed the proposed Development Plan Package. Engineering Division does not recommend approval of the Development Plan Package at this time. This review falls under Development Standard 2-01. The following items need to be addressed:

SITE PLAN:

1) DS Sec.2-01.3.3: The relevant Development Plan Package number (DP13-0006) may be added to the lower right hand corner of the plan on all sheets.

2) DS Sec.2-01.3.7.A.8: Revise the development plan document to provide the subdivision plat number S13-002 adjacent to the title block on each sheet.

3) DS Sec.2-01.3.9.O: Revise the development plan document to clearly show all existing canopies on the site plan sheet. Verify that all structures are permitted and in conformance with all PDSD Sections.

4) Engineering acknowledges that cross access & cross parking is to be provided per recorded covenants, conditions and restrictions (CC&Rs) under the Final Plat. Provide the recordation information in all appropriate places on Sheet 1 once the document has been recorded.

GENERAL COMMENTS:

Please provide a revised Development Plan Package that addresses the comments provided above. For expedite purposes the development plan package can be reviewed over the counter (PDSD Engineering Division comment only) for stamp approval once all items have been addressed. Please call to schedule an appointment when ready.



Jason Green, CFM
Senior Engineer Associate
Engineering Division
Planning & Development Services Department
02/11/2013 PGEHLEN1 OTHER AGENCIES PIMA ASSN OF GOVTS Approved Here are my comments -

DATE: 2/11/2013
CASE: DP13-0006 COPE COMMUNITY SERVICES - TENTATIVE PLAT
COMMENT: No objections or adverse comments

Daily PM Peak
Vehicle Trip Generation: 0 0

Thanks,
-Eric

Additional notes: No changes in trip generation
02/13/2013 PGEHLEN1 POLICE REVIEW Approved I have no issues with this proposal.

CSO Becky Noel #37968
Tucson Police Dept
837-7428
02/19/2013 JOHN BEALL COT NON-DSD COMMUNITY PLANNING Passed
02/20/2013 RONALD BROWN H/C SITE REVIEW Approved
02/21/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Approved
02/22/2013 ANDREW CONNOR LANDSCAPE REVIEW Reqs Change Note: Existing development on the site is subject to the zoning regulations in effect at the time the existing development received zoning approval per LUC 3.7.1.2.B

2. Ensure that all Zoning and Engineering comments and concerns are addressed

3. Additional comments may apply
02/25/2013 ED ABRIGO PIMA COUNTY ASSESSOR Denied Office of the Pima County Assessor
115 N. Church Ave.
Tucson, Arizona 85701

BILL STAPLES
ASSESSOR




TO: CDRC Office
Subdivision Review
City of Tucson (FAX# 791-5559)

FROM: Suzanne Gilpin
GIS Cartographer
Pima County Assessor's Office


DATE: February 25, 2013


RE: Assessor's Review and Comments Regarding Tentative Plat
DP13-0006/COPE COMMUNITY SERVICES


* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *

Plat meets Assessor's Office requirements.
___X___ Plat does not meet some of Assessor's Office requirements.
(See Comments below)


COMMENTS:

" Must be a section tie, with a bearing and dimension from the section corner or quarter corner to the point of tie on the subdivision.
" All hatching, stippling, striping etc. must be removed in the final plat, unless another agency requires it. If so all lettering must have the hatching, etc. cut away so they are legible.
" All adjacent subdivisions should be named, with map and plat in the appropriate areas around the subdivision.







NOTE: THE ASSESSOR'S CURRENT INVOLVEMENT IN PROCESSING ITS MANUAL MAPS TO DIGITAL FORMAT IS EXPEDITED GREATLY BY EXCHANGE OF DIGITAL DATA. IN THE COURSE OF RECORDING THIS SUBDIVISION YOUR ASSISTANCE IN PROVIDING THIS OFFICE WITH AN AUTOCAD COPY WOULD BE GREATLY APPRECIATED. THANK YOU FOR ANY DIGITAL DATA PREVIOUSLY SUBMITTED.
02/25/2013 PGEHLEN1 UTILITIES SOUTHWEST GAS Approved See comment letter in SIRE
02/26/2013 PGEHLEN1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Approved January 31, 2013

Cypress Civil Development
2102 N. Country Club Road, Suite 9
Tucson, AZ 85716

Attn: Kevin M. Hall

SUBJECT: Water Availability for project: Cope Community Services, APN: 138240860, Case #: DP 13-0006, A, T-15, R-13, SEC-15, Lots: 10, Location Code: TUC, Total Area: 4.8ac, Zoning: I-1

WATER SUPPLY
Tucson Water will provide water service to this project based on the subject zoning of the above parcels. Tucson Water has an assured water supply (AWS) designation from the State of Arizona Department of Water Resources (ADWR). An AWS designation means Tucson Water has met the criteria established by ADWR for demonstration of a 100-year water supply - it does not mean that water service is currently available to the subject project.

WATER SERVICE
The approval of water meter applications is subject to the current availability of water service at the time an application is received. The developer shall be required to submit a water master plan identifying, but not limited to: 1) Water Use; 2) Fire Flow Requirements; 3) Offsite/Onsite Water Facilities; 4) Loops and Proposed Connection Points to Existing Water System; and 5) Easements/Common Areas.

Any specific area plan fees, protected main/facility fees and/or other needed facilities' cost, are to be paid by the developer. If the existing water system is not capable of meeting the requirements of the proposed development, the developer shall be financially responsible for modifying or enhancing the existing water system to meet those needs.

This letter shall be null and void two years from the date of issuance.

Issuance of this letter is not to be construed as agency approval of a water plan or as containing construction review comments relative to conflicts with existing water lines and the proposed development.

If you have any questions, please call New Development at 791-4718.

Sincerely,


Scott Schladweiler, P.E.
Engineering Manager
Tucson Water Department

SS:mg
CC:File
02/26/2013 PGEHLEN1 UTILITIES EL PASO NATURAL GAS Passed
02/26/2013 PGEHLEN1 OTHER AGENCIES TUCSON AIRPORT AUTHORITY Passed
02/26/2013 PGEHLEN1 UTILITIES CENTURYLINK Passed
02/26/2013 JANE DUARTE COT NON-DSD PARKS & RECREATION Passed
02/26/2013 LIZA CASTILLO UTILITIES TUCSON ELECTRIC POWER Denied SUBJECT: COPE COMMUNITY SERVICES TENTATIVE PLAT
DP13-0006


Tucson Electric Power Company (TEP) has reviewed the Tentative plat submitted January 28, 2013. TEP is unable to approve the plat at this time. TEP has requested that certain easements identified as Public Utility Easements be relabeled as TEP easements.

Please forward any future submittals of this plat to our office.

If you have any questions, please contact me at 917-8744.

Thank you,

Mary Burke
Right of Way Agent
Tucson Electric Power Co.
Mail Stop HQW603
PO Box 711, Tucson, AZ 85702
Office - 520-917-8744
Cell - 520-401-9895
mburke@tep.com<mailto:mburke@tep.com>
02/26/2013 ROBERT YOUNG PIMA COUNTY PIMA CTY - DEV REVIEW Passed
02/26/2013 PATRICIA GEHLEN ZONING-DECISION LETTER REVIEW Reqs Change The review has been completed and revisions are required. 4 rolled sets of the revised tentative plat, comment letter, disk with all plans and documents submitted and all other items requested by review staff must be included with the 2nd submittal of these plans.
02/26/2013 PGEHLEN1 OTHER AGENCIES U. S. POST OFFICE Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
05/03/2013 CPIERCE1 REJECT SHELF Completed
02/27/2013 CPIERCE1 APPROVAL SHELF Completed