Permit Review Detail
Review Status: Completed
Review Details: SITE and/or GRADING
Permit Number - DP12-0150
Review Name: SITE and/or GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/13/2012 | RBROWN1 | ADA | REVIEW | Passed | |
| 10/01/2012 | RONALD BROWN | H/C SITE | REVIEW | Denied | 1. Decomposed granite is certainly an acceptable material for accessible routes under certain construction conditions, sub base at 95% compaction, DG at 95% compaction and bordered on both sides to prevent spreading. a. Please provide a cross section construction detail. 2. Please provide grade elevations through out the accessible route to show slope compliance with ICC A 117.1, Section 403.3, 5% max running slopes and 2% max cross slopes. 3. Please show accessible parking space, aisle and access to accessible route. a. Please provide accessible parking sign, slopes in parking area of not more than 2% in all directions and that the accessible parking space is a "Van Accessible" parking space. END OF REVIEW |
| 10/02/2012 | ANDREW CONNOR | LANDSCAPE | REVIEW | Approved | |
| 10/02/2012 | ANDREW CONNOR | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/04/2012 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |