| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/27/2012 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 08/06/2012 | STEVE SHIELDS | ZONING | REVIEW | Approv-Cond | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: TEP Prairie Fire Solar Development Package (2nd Review) DP12-0085 TRANSMITTAL DATE: August 6, 2012 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. The Zoning Review Section conditionally approves the development plan for this project, subject to the following changes on the sign-off copies. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements 2. D.S. 2-01.3.4.C Label the section corners on the location map. 3. D.S. 2-01.3.8.B Provide a reference on the overall site plan indicating that all recordation information is provided on sheet X. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ DP12-0085 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 08/06/2012 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Approv-Cond | DATE: August 6, 2012 TO: Jim Campbell P.E. SUBJECT: Prairie Fire SOLON TEP Solar Project Engineering Resubmittal Meeting Review ADDRESS: 7540 S OLD VAIL RD LOCATION: T15S, R15E, Section 21 REVIEWER: Elizabeth Leibold CASE: DP12-0085 SUMMARY: PDSD Engineering Division has reviewed the Development Package for the Prairie Fire Solar Project in a meeting with consultants 6AUG12, and maintains a recommendation of conditional approval. Project is impacted by the Rita Ranch Master Drainage Report and associated annexation Ordinance 6143. CONDITIONS OF APPROVAL: 1) DS Sec.2-01.3.8.F: Address the following clarifications in the Drainage Report: a) DS Sec.10-02.2.3.1.2.F.1: Submit copy of response from ACOE and provide 2 copies of sealed statement for Drainage Report stating that there are no 404 watercourses on the project site and that project is in compliance with 404 regulations. 2) DS Sec.2-01.3.8.I: Address the following drainage comments on the plans: a) Add note that filter fabric is needed with proposed rip rap applications. b) Add to basin details the required erosion protection for unattenuated flow conditions - at minimum rip rap with filter fabric to 100-yr WSEL plus freeboard is needed to direct flows to weir. 3) DS Sec.2-01.3.7.A.7: The property is subject to annexation requirements; provide the applicable annexation file number, in the lower right corner of each sheet. List the applicable conditions of approval as a note. Development Plan with Landscape Plan & Grading Plan is required per Annexation. Provision and participation in the improvement district for maintaining public infrastructure is also referenced in the Annexation (Ord.6143). The City has not yet determined if a provision will be imposed for this project. 4) Address the following note comments on the cover sheet and plan view ALTA sheet or grading plan sheet: a) Clarify Basis of Elevation. Elevation with datum should be provided that matches drainage report and/or provide explanation of datum. Rotated boundary data is confusing; clarify/explain or correct boundary data to match title report and/or ALTA - provide one or the other with resubmittal. For resubmittal, to show compliance for conditional approval, provide 2 sets of plans, 2 copies of reports or other documentation, and a response letter. If you have any questions, call me at 837-4934. Elizabeth Leibold, PE, CPM, CFM Civil Engineer Engineering Division Development Services Department City of Tucson |
| 08/10/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | Minor revisions required for irrigation proposal, NUOS areas, and other notes per August 6th meeting. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/13/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |