Permit Review Detail
Review Status: Completed
Review Details: DEV PKG
Permit Number - DP12-0085
Review Name: DEV PKG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2012 | FERNE RODRIGUEZ | START | PLANS SUBMITTED | Completed | |
| 06/06/2012 | FRODRIG2 | WWM | REVIEW | Passed | |
| 06/07/2012 | RONALD BROWN | ADA | REVIEW | Passed | |
| 06/26/2012 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 06/27/2012 | RONALD BROWN | ZONING HC | REVIEW | Approved | |
| 06/27/2012 | STEVE SHIELDS | ZONING | REVIEW | Denied | CDRC TRANSMITTAL TO: Planning and Development Services Department Plans Coordination Office FROM: Steve Shields Lead Planner PROJECT: TEP Prairie Fire Solar Development Package (1st Review) DP12-0085 TRANSMITTAL DATE: June 27, 2012 DEVELOPMENT PLAN COMMENTS: Please resubmit revised drawings along a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. 1. This development package was reviewed for full code compliance with the City of Tucson Development Standards (D.S.) and Land Use Code (LUC) for the entire site. 2. It appears that a portion of this proposed Renewable Energy Generation is located within the RX-1 zone. If this is the case per LUC Section 2.3.2.3.C Renewable Energy Generation "38", subject to: Sec. 3.5.11.2.B., C., D., and E. and approval through a Zoning Examiner Full Notice Procedure, Sec. 23A-50 and 23A-53, requires a Special Exception. Until comment 12 is addressed the requirement for the Special Exception cannot be verified. If a Special Exception is required the development package cannot be approved until the Special Exception is approved. If the Special Exception is required and approved provide the case number, date of approval, and any conditions of approval on the cover sheet of the development package. The following comments are based on the "LAYOUT TO BE USED WITH A DEVELOPMENT PACKAGE SUBMITTAL (DS 2-01) dated 12-2009. This layout document can be viewed @ http://cms3.tucsonaz.gov/files/dsd/DevPackageSubmittalLayout.pdf; 3. The sheet order is not correct. All general notes are to be on the cover sheet or a sheet following the cover sheet, organized under a heading indicating which plan the note(s) are for, i.e. site, grading, etc. The Native Plant Preservation plan should follow the Landscape plans. The following comments are based on Development Standard 2-01.0: 4. D.S. 2-01.2.2 & D.S. 2-01.2.10 Due to the overall size of the project property, provide an overall key plan on the cover sheet that shows the entire property and also provides the requirements of D.S. 2-01.3.8.A & D.S. 2-01.3.9.F. 5. D.S. 2-01.3.2.D Zoning acknowledges that D.S. 2-01.3.2.D states that an administrative street address is to be provided in the title block. After discussion with Pima County Addressing the administrative street address is to be provided adjacent to the title block. That said provide an administrative address adjacent to the title block. 6. D.S. 2-01.3.3 Provide the following relevant case numbers on the plan adjacent to the title block on all sheets, DP12-0085 7. D.S. 2-01.3.4 Provide a location map that meets the requirements of D.S. 2-01.3.4. 8. D.S. 2-01.3.5 When the development package documents consists of more than one (1) sheet, a sheet index (a legible drawing of the site showing the area represented on each sheet) is to be placed on the cover sheet or the second sheet, see comment 4. 9. D.S. 2-01.3.7.A.4 Depending on how comment 2 & 12 are addressed and if part of the project is within the RX-1 zoned property provide the following information under "ZONING AND LAND USE NOTES" #3 Renewable Energy Generation "38", subject to: Sec. 3.5.11.2.B., C., D., and E. and approval through a Zoning Examiner Full Notice Procedure, Sec. 23A-50 and 23A-53. 10. D.S. 2-01.3.7.A.6.b As this property has street frontage along Old Vail Road provide a general note on the plan stating "THIS PROJECT IS DESIGNED TO MEET THE OVERLYA ZONE(S) CRITERIA; SEC. 2.8.3, MAJOR STREETS AND ROUTES (MS&R) SETBACK ZONE". 11. D.S. 2-01.3.8.B For all easements shown on the plan provide the recordation information on the site plan. 12. D.S. 2-01.3.9.F All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined. 13. D.S. 2-01.3.9.H.5 Demonstrate on the site plan how the requirements of LUC Section 3.3.6.9 are met. 14. D.S. 2-01.3.9.H.5 Per LUC Section 3.3.6.4.A the minimum width for the parking area access lane (PAAL) is twenty-four (24) feet when the vehicle parking spaces are at 90 degrees to the PAAL. That said provide a PAAL width dimension on the site plan at the proposed vehicle parking spaces. 15. D.S. 2-01.3.9.H.5.a Provide a fully dimensioned vehicle parking space detail. 16. Demonstrate how the requirements LUC Section Sec. 3.5.11.2. E are met. If you have any questions about this transmittal, please Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com Sshield1 on DS1/planning/New Development Package/ DP12-0085 RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
| 06/28/2012 | ZELIN CANCHOLA | COT NON-DSD | TRAFFIC | Approved | |
| 07/03/2012 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | TO: Jim Campbell P.E. SUBJECT: Prairie Fire SOLON TEP Solar Project Engineering Review ADDRESS: 7540 S OLD VAIL RD LOCATION: T15S, R15E, Section 21 REVIEWER: Elizabeth Leibold CASE: DP12-0085 SUMMARY: PDSD Engineering Division has reviewed the Development Package for the Prairie Fire Solar Project and recommends conditional approval. Project is impacted by the Rita Ranch Master Drainage Report and associated annexation Ordinance 6143. For this solar project, a SWPPP and Floodplain Use Permit application will be needed for resubmittal. CONDITIONS OF APPROVAL: 1) DS Sec.2-01.3.8.F: Address the following clarifications in the Drainage Report: a) DS Sec.10-01.2.1: Add to the report that the project is within the Julian Wash Watershed which is a Balanced Basin Management Watershed. b) DS Sec.10-01.2.2: Clarify detention & retention requirements in report by addressing the following comments: i) Per the Rita Ranch Master Drainage Report, the Rita Ranch Regional Detention Basin allows for 190 cfs allocated for runoff to this regional basin from an 28.9 acre site to the north of this regional basin. State that the project does not exceed this requirement. ii) State that the project does not need to provide detention or retention for the watershed that enters the Regional Basin per the Rita Ranch Master Drainage Report. c) State whether the downstream condition, on the north side of the project, increases Q100 leaving the site on the north side for proposed conditions. 2) DS Sec.2-01.3.8.I: Address the following drainage comments on the plans: a) Label on planview for site and grading plan sheets, the following information: i) floodplain information, including the location of the developed condition 100-year flood limits for all flows of 100 cfs or more with 100-year flood water surface elevations; and ii) water surface contours for existing floodplain areas for the 100-year flood with water surface elevations; and iii) W.A.S.H. Ordinance watercourse label offsite on planviews; and iv) W.A.S.H. Ordinance 50-ft Setback line within property limits. b) DS Sec.10-01.3.5.1.3.a: Hydrologic soil type D is indicated on soils maps which typically do not provide for basin drain down times meeting City standards of under 12 hours. Provide an orifice plate for the 12-in bleed pipe for basin and show on detail PD01 on sheet 7. c) Per the Rita Ranch Master Drainage Report, drainage easements may be needed, including maintenance access easement for the Rita Ranch Regional Detention Basin. Unless there is another access easement from Valencia Road, provide by delineation and labeling, an access easement across a portion of access area for Public Drainage Maintenance Access, from northeast access easement to south corner of project along proposed access road. Provide the recordation sequence number information on plan view. Provide gate opening at this corner of the project. 3) DS Sec.2-01.3.7.A.7: The property is subject to annexation requirements; provide the applicable annexation file number, in the lower right corner of each sheet. List the applicable conditions of approval as a note. Development Plan with Landscape Plan & Grading Plan is required per Annexation. Provision and participation in the improvement district for maintaining public infrastructure is also referenced in the Annexation (Ord.6143). The City has not yet determined if a provision will be imposed for this project. 4) Address the following note comments on the cover sheet: a) Clarify Basis of Bearing and Basis of Elevation. Elevation with datum should be provided that matches drainage report and/or provide explanation of datum. Rotated boundary data is confusing; clarify/explain or correct boundary data to match title report and/or ALTA - provide one or the other with resubmittal. b) DS Sec.2-01.3.7.B.1: Drainage Notes. List the following notes under Drainage Notes This project is affected by the City of Tucson Floodplain Regulations. A floodplain use permit is required for the project. 5) DS Sec.11-01.4.C: Address the following grading related comments: a) LUC Sec.3.7.2.7: Disturbed areas are required to be reseeded as stated in previous meetings. Show and label and add as notes that there will be reseeding for all disturbed areas for this project to the following plans: LA-01, General Grading Note on sheet 7, Sheet 4, and cover sheet. b) Tucson Code Chap.26 Art.2: On sheet 7, Detail GD03 shows built up fill against silt fence - this is not acceptable due to concentrated flows that would occur for this design. Provide standard drain rock (which is typically also not feasible or used) or show that ground is flattened to allow stormwater to actually flow through the silt fence as the silt fence is intended to do. c) For inspection purposes, provide several dimensions for basin, and outlet channel structure on plan view sheet 4. d) Label rock size and thickness (min 2 D50) for detail PD02. For resubmittal, to show compliance for conditional approval, provide 2 sets of plans, 2 copies of reports or other documentation, and a response letter. If you have any questions, call me at 837-4934. Elizabeth Leibold, PE, CPM, CFM Civil Engineer Engineering Division Development Services Department City of Tucson |
| 07/03/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1) In addition to the requirements of Sec. 3.7.3., Landscaping and Screening Regulations, there must be a decorative masonry wall at least six (6) feet in height between the project site and any residential zone. LUC 3.5.11.2.E. Revise the plans to provide screening for the SR zoning to the north and the RX-1 zoning. 2) DS 2-01.3.8.C Provide the following information regarding existing private or public right-of-way adjacent to or within the site: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks. 3) A 10' wide street landscape border per LUC 3.7.2.4.A is required along the entire Pantano Rd. frontage. Label and dimension any proposed natural or constructed landscape borders. If there is a street to the north, a border is required in that location also. 4) Revise the native plant preservation plans to show the limits of grading. DS 2-15.3.4.A Revise the landscape plans to show the limits of grading. DS 2-07.2.2.B.5 Indicate natural contours of undisturbed areas. DS 2-07.2.2.B: 5) Submit an irrigation plan. LUC 3.7.4.5.C 6) Landscape plans shall include a summary of plants required for mitigation and show their site location on the landscape plans. Show the total PIP, TOS, required mitigation for each species. DS 2-15.3.4.B 7) Fencing shall be required during construction for all undisturbed natural desert areas and for individual Protected Native Plants to be preserved-in-place. The area to be fenced shall be beyond the "drip-line" of the vegetation by one-half (½) the distance of the "drip-line" radius. DS 2-15.6.A 8) Revise the native plant inventory to use the ratings for viability and transplantability in DS 2-15.3.2. 9) Revise the Native Plant Inventory to note the disposition of all protected native plants per DS 2-15.3.4. Use the standard abbreviations PIP, TOS, or RFS for each plant. Consider also transferring these designations to the symbols on the aerial photo. 10) All Protected Native Plants shall be planted in locations able to support their long-term health and survival and shall be planted in densities and configurations to approximate the natural character of the Sonoran Desert. LUC 3.8.6.6.C The mass plantings of barrel cactus along the east property boundary do not comply with the standard. 11) Revise the calculations on the native plant preservation plan. See the Native plant Preservation Worksheet in DS 2-15. 12) The landscape plan must include the following grading Information per DS 2-07.2.2.B: 1. Grade changes across the site indicated by one (1) foot interval contour lines or by spot elevations. 2. Percent slope across the site and the direction of the slope of paved areas. 3. Existing grades on adjacent rights-of-way and adjacent sites and propsed finish grades. 4. Limits of grading. Indicate natural contours of undisturbed areas. 5. Areas of detention/retention, depths of basins, and percentage of side slope or slope ratio. 6. Water harvesting areas. 7. Percent side slope or slope ratio of berms. AND remove the photo layer on the drawing. 13) Revise note 6 on the Native Plant Preservation Plan to include the new phone number (520) 837-4989. 14) Revise note 7 on the Native Plant Preservation Plan to clarify that each phase complies with all requirements as a separate entity. DS 2-05.2.4.C 15) Revise the landscape plan to include calculations for the length and width of landscape borders and number of canopy trees per length and the square footage of all landscaped borders and a calculation of the percentage of vegetative coverage. DS 2-07.2.2. |
| 07/03/2012 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | TO: Jim Campbell P.E. SUBJECT: Prairie Fire SOLON TEP Solar Project Engineering Review ADDRESS: 7540 S OLD VAIL RD LOCATION: T15S, R15E, Section 21 REVIEWER: Elizabeth Leibold CASE: DP12-0085 SUMMARY: PDSD Engineering Division has reviewed the Development Package for the Prairie Fire Solar Project and recommends conditional approval. Project is impacted by the Rita Ranch Master Drainage Report and associated annexation Ordinance 6143. For this solar project, a SWPPP and Floodplain Use Permit application will be needed for resubmittal. CONDITIONS OF APPROVAL: 1) DS Sec.2-01.3.8.F: Address the following clarifications in the Drainage Report: a) DS Sec.10-01.2.1: Add to the report that the project is within the Julian Wash Watershed which is a Balanced Basin Management Watershed. b) DS Sec.10-01.2.2: Clarify detention & retention requirements in report by addressing the following comments: i) Per the Rita Ranch Master Drainage Report, the Rita Ranch Regional Detention Basin allows for 190 cfs allocated for runoff to this regional basin from an 28.9 acre site to the north of this regional basin. State that the project does not exceed this requirement. ii) State that the project does not need to provide detention or retention for the watershed that enters the Regional Basin per the Rita Ranch Master Drainage Report. c) State whether the downstream condition, on the north side of the project, increases Q100 leaving the site on the north side for proposed conditions. 2) DS Sec.2-01.3.8.I: Address the following drainage comments on the plans: a) Label on planview for site and grading plan sheets, the following information: i) floodplain information, including the location of the developed condition 100-year flood limits for all flows of 100 cfs or more with 100-year flood water surface elevations; and ii) water surface contours for existing floodplain areas for the 100-year flood with water surface elevations; and iii) W.A.S.H. Ordinance watercourse label offsite on planviews; and iv) W.A.S.H. Ordinance 50-ft Setback line within property limits. b) DS Sec.10-01.3.5.1.3.a: Hydrologic soil type D is indicated on soils maps which typically do not provide for basin drain down times meeting City standards of under 12 hours. Provide an orifice plate for the 12-in bleed pipe for basin and show on detail PD01 on sheet 7. c) Per the Rita Ranch Master Drainage Report, drainage easements may be needed, including maintenance access easement for the Rita Ranch Regional Detention Basin. Unless there is another access easement from Valencia Road, provide by delineation and labeling, an access easement across a portion of access area for Public Drainage Maintenance Access, from northeast access easement to south corner of project along proposed access road. Provide the recordation sequence number information on plan view. Provide gate opening at this corner of the project. 3) DS Sec.2-01.3.7.A.7: The property is subject to annexation requirements; provide the applicable annexation file number, in the lower right corner of each sheet. List the applicable conditions of approval as a note. Development Plan with Landscape Plan & Grading Plan is required per Annexation. Provision and participation in the improvement district for maintaining public infrastructure is also referenced in the Annexation (Ord.6143). The City has not yet determined if a provision will be imposed for this project. 4) Address the following note comments on the cover sheet: a) Clarify Basis of Bearing and Basis of Elevation. Elevation with datum should be provided that matches drainage report and/or provide explanation of datum. Rotated boundary data is confusing; clarify/explain or correct boundary data to match title report and/or ALTA - provide one or the other with resubmittal. b) DS Sec.2-01.3.7.B.1: Drainage Notes. List the following notes under Drainage Notes This project is affected by the City of Tucson Floodplain Regulations. A floodplain use permit is required for the project. 5) DS Sec.11-01.4.C: Address the following grading related comments: a) LUC Sec.3.7.2.7: Disturbed areas are required to be reseeded as stated in previous meetings. Show and label and add as notes that there will be reseeding for all disturbed areas for this project to the following plans: LA-01, General Grading Note on sheet 7, Sheet 4, and cover sheet. b) Tucson Code Chap.26 Art.2: On sheet 7, Detail GD03 shows built up fill against silt fence - this is not acceptable due to concentrated flows that would occur for this design. Provide standard drain rock (which is typically also not feasible or used) or show that ground is flattened to allow stormwater to actually flow through the silt fence as the silt fence is intended to do. c) For inspection purposes, provide several dimensions for basin, and outlet channel structure on plan view sheet 4. d) Label rock size and thickness (min 2 D50) for detail PD02. For resubmittal, to show compliance for conditional approval, provide 2 sets of plans, 2 copies of reports or other documentation, and a response letter. If you have any questions, call me at 837-4934. Elizabeth Leibold, PE, CPM, CFM Civil Engineer Engineering Division Development Services Department City of Tucson |
| 07/09/2012 | MARTIN BROWN | COT NON-DSD | FIRE | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/23/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |