Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.1
Permit Number - TS-PRM-0623-00370
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/29/2023 | Commercial Electrical | APPROVED | |||
06/30/2023 | Sign Post Review | PENDING ASSIGNMENT | |||
06/30/2023 | Commercial Building | REQUIRES RESUBMIT | Please respond to the following: 1. BESIDES THE SK1 DETAIL DRAWING, PROVIDE A SIDE VIEW DETAIL DRAWING OF THE TRIANGULAR FRAME MATCHING WHAT THE SIGN MAKER IS SHOWING MARKED "A". 2. Do provide a zoomed in detail drawing showing what is provided structurally to receive the individual letters, how is letter mounted to the frame. 3.Please resubmit. |
||
06/26/2023 | Signs | REQUIRES RESUBMIT | RE: canopy sign review For: Corbett’s AT: 345 N 5th Av / Zoned I-1 (4 to 1 ratio sign area) Permit: TS-PRM-0623-00370 Date: 06/26/23 Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov Codes: Unified Development Code (7A) Sign Standards, National Electrical Code (NEC) 600, Tucson-Pima County Outdoor Lighting Code (OLC), International Building Code (IBC) 2018 1. UDC: A) I acknowledge the sign area proposed is allowed, thank you. B) lower the sign mount so that it is positioned directly atop the canopy, to avoid falling under criteria of 7A.8.2 roof signage C) update elevation diagram to show the new Corbett sign is below the midpoint of the roof pitch behind the canopy (still has the old Love Burger on it) D) for permit record, dimension the length of the frontage for this establishment along 7th St and include the outdoor dining area, and dimension along 5th Av as well 2. NEC: add standards notes: (note, neon is being reviewed by electrical reviewer) A) dedicated sign circuit shall be provided at breaker panel and shall be labeled B) sign shall have UL sticker, manufacturer sticker and installer sticker on the sign C) add note sign lettering to have weep holes 3. OLC: A) add note: timer shall be shown to inspector and set to midnight curfew 4. IBC: A) engineering for mount to the bracing system reviewed by structural division Depending on revisions resubmitted, further review comments may be forthcoming. I may be reached at Heather.Thrall@tucsonaz.gov if you have any questions. |