Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TS-PRM-0623-00359
Parcel: 138041810

Address:
6500 S 12TH AV

Review Status: Requires Resubmit

Review Details: PERMANENT SIGN REVIEW v.1

Permit Number - TS-PRM-0623-00359
Review Name: PERMANENT SIGN REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/27/2023 Signs REQUIRES RESUBMIT RE: repair review / insert two digital cabinets into monument signs
AT: 6500 S 12th Ave / Speedway Gas Station
Sign permit: TS-PRM-0623-00359
Date: 06/27/23
Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov)

Codes: Unified Development Code (UDC 7A, Sign Standards), National Electrical Code (NEC) 600, International Building Code (IBC) 2018, Outdoor Lighting Code (OLC)

1) UDC:
A) Please update the permit application to be a repair permit, rather than change of copy.

2) NEC:
A) add all standard electrical notes - volts, amps - tie into existing sign circuit and existing shut off switch

B) indicate unit is UL component

3) OLC:
A) add standard outdoor lighting code notes: 4400k temp max during the day, dim from sunset to midnight curfew or to sunrise if 24 hour establishment via the photocell and or timer provided

B) timer shall be shown to inspector - must be provided, even if 24 hour establishment

4) IBC:
A) add notes how the insert is going to be mounted within the frame on the last sheet of the submittal - i.e. the screws / size used ?

Please email me when you have resubmitted so I can pull your revision for faster review. Thank you.