Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: PERMANENT SIGN REVIEW v.2
Permit Number - TS-PRM-0523-00298
Review Name: PERMANENT SIGN REVIEW v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
08/03/2023 | Signs | REQUIRES RESUBMIT | RE: sign review For: Presidio Palms Apartments AT: 475 N Granada Sign permit: TS-PRM-0523-00298 Date: 05/17/23 (1st review) Date: 2nd review – 08/3/23 Reviewer: H. Thrall (Heather.Thrall@tucsonaz.gov) Codes: Unified Development Code 7A, Sign Standards, National Electrical Code (NEC) 600, Pima County -Tucson Outdoor Lighting Code, International Building Code 1. UDC: A) The sign height and setback have been adjusted to monument sign standards, thank you. And I acknowledge the sign dimensions will lead to 50 square feet monument sign area. B) PRIOR COMMENT – UNADDRESSED: This location was converted to apartments and the developer's team was prior informed that the freeway sign cabinet required removal, as a freeway sign is not permitted for a multi-family use. Please note freeway cabinet sign removal on the plans, and that the nonconforming pole sign is intending to be replaced with this new sign request. C) please point out all existing signs at the site on the location plan. (interior site signs that are near building) (just add google street view of the freestanding sign on the lawn next to the building and note “interior site sign existing, to remain” D) the base is missing from the proposed view, please add to match the construction view 3. NEC: 600 A) a data layer appears to be missing, please add the volts, amps, circuit B) add note dedicated sign circuit is provided and labeled at power panel C) add note UL sticker, manufacturer sticker and installer sticker to be added to sign D) add note – using power from prior freestanding sign E) clarify what is illuminated with this sign, i.e. the letters only, or is the logo lit and is there any halo light or all enclosed? F) add note for service access location on cabinet 4. OLC - no comments, thank you 5. IBC: A) please provide engineered plans and calculations for the sign due to surface area size, thank you B) provide notations that support poles are high strength steel C) provide note that 6” clear from bottom of each caisson to bottom of pipe for gravel / rock D) Need all attachments for letters to cabinet, if push – thru, reveal depth, etc. E) need details for how sign cabinetry is mounted and how may points, i.e. engineering F) clarify if the base is capped or is this open to elements? Please email when resubmitting, and I’ll pull plans faster for review. Please reach out to me with any questions you may have. |