05/18/2026 Signs Standard APPROVED
05/04/2026 Commercial Electrical Fast NOT REQUIRED Non-illuminated sign.
05/04/2026 Outdoor Lighting Standard NOT REQUIRED Non-illuminated sign.
05/11/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please provide structural engineering calculations and a detailed anchoring pattern for the proposed pan channel letters. The submittal must demonstrate that the chosen fasteners (type, size, and quantity) are sufficient to resist wind and dead loads per 2024 IBC Chapter 16. Please provide the following specific information with the next submittal.
Specific Requirements related to above. IBC 107.2.7
2. Anchoring Pattern: Provide an elevation view for a typical letter showing the exact location and spacing of all fasteners.
3. Calculations: Include calculations for the worst case (largest/heaviest) letter, addressing:
A. Wind Load: Calculated based on the local design wind speed as amended.
B. Dead Load: Weight of the sign, including internal components (LEDs, transformers).
C. Substrate Capacity: Verify the capacity of the fasteners (e.g., expansion anchors, lag bolts, or toggle bolts) when installed into the specific wall substrate (brick, stucco, wood, etc.).
3. Fastener Specifications: Clearly identify the fastener material (must be corrosion-resistant), diameter, and minimum embedment depth.

Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson