| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2026 | ROW Engineering Review - Standard | REQUIRES RESUBMIT | See comments on TCP. 1.This closure will require night work. 2. Panels do not align with setup. 3. Return westbound traffic to its normal through lanes before the 6th Avenue intersection while maintaining the eastbound left-turn lane and establish westbound lane alignment before vehicles enter the intersection . If sufficient transition distance is unavailable, revise the TCP to extend the center-lane closure east of 6th Avenue to allow more room for traffic to return to normal lanes. Show how the revised setup will accommodate queues and prevent lane changes within the intersection. 4. Address sidewalk on Northside of 22nd St. Pathway must stay open |
||
| 10/07/2026 | Archeological Sensitivity - Standard | REVIEW COMPLETED | archaeological monitoring required | ||
| 09/28/2026 | Historic | REVIEW COMPLETED | |||
| 10/19/2026 | Sun Tran Review - Standard | REVIEW COMPLETED | Not holding for Sun Tran review, see conditions for more information regarding Sun Tran | ||
| 09/24/2026 | Transportation Application Review Express | REVIEW COMPLETED |