Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-UTL-0325-00368
Parcel: 11612152B

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.3

Permit Number - TR-UTL-0325-00368
Review Name: RIGHT-OF-WAY REVIEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/20/2025 Transportation Application Review Express PENDING ASSIGNMENT
03/20/2025 ROW Engineering Review - Standard REQUIRES RESUBMIT Traffic Control Plan Notes - Full Channel Shift for Night work.
1) Posted Speed limit on Speedway is 35 mph - Review Tapers & Tangents based on this. Not on the Reduced speed for 25 mph.
2) How is Residential access to home within closure area being maintained.
3) Provide solid closure of Devices at Riverview median where transition occurs. to prevent cross traffic movement
4) Extend Device line on EB Speedway @ Melrose Ave for min 120' at the return shift. (On Page #2 of Plan Set)
5) Note that TNE will be required for proposed Night Work and Coordination with Sun Tran bus route will be required.