Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TR-ROW-1025-01296
Parcel: 12705033B

Address:
4739 E 4TH ST

Review Status: Approved

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-1025-01296
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
10/30/2025 ROW Engineering Review - Standard APPROVED E 4th St is under Pavement Moratorium
*New individual service line connections and individual service line repairs may be made in new pavements without a moratorium patch requirement provided the backfill and pavement repair includes NO native backfill and the pavement area affected is less than 4-ft wide to complete the T-Top Patch Detail. If the width exceeds the 4-ft maximum width, the area of patch must comply with moratorium patch requirements. Where cuts to pavement under moratorium occur due to an emergency, Utilities may follow the non-moratorium pavement repair requirements described above in lieu of the requirements in section 10.3.2.
10/22/2025 Transportation Application Review Express REVIEW COMPLETED