| 08/03/2026 | ROW Engineering Review - Standard | PENDING ASSIGNMENT | |||
| 08/03/2026 | Transportation Application Review Express | REQUIRES RESUBMIT | Please reattach a revised site plan that includes an aerial view clearly identifying and marking the exact location where the proposed work will be performed. Additionally, please revise the proposed curb cut dimensions. Per Sec. 25-38, Special Requirements in Residential Districts, the maximum allowable curb cut width, including the wings, is 20 feet. Please ensure the proposed curb cut complies with the following residential standards: Minimum curb cut width: 10 feet Maximum curb cut width : 20 feet Maximum curb cut width for two adjoining properties: 30 feet Minimum distance between curb cuts: 12 feet Minimum distance from street light standards or catch basins: 5 feet Minimum distance from a fire hydrant or City water hydrant: 20 feet Minimum distance from the end of a curb return: 4 feet |