05/08/2026 DTM Electrical - Standard PENDING ASSIGNMENT
05/08/2026 MITZ District - Standard PENDING ASSIGNMENT
05/08/2026 PIA Engineering Review - Standard PENDING ASSIGNMENT
05/06/2026 Transportation Application Review Express PENDING ASSIGNMENT
05/08/2026 ROW Engineering Review - Standard REQUIRES RESUBMIT DTM Review Comments - Required for Review Completion-
1) REQUIRED - Upload PIA and DEV Construction plan packets showing HAWK Crossing Build.
2) Review Traffic Control Plan Redline comments -
Plan #2 Phase 2 - For Traffic Safety - Review to prevent Cross traffic through closure.. Barricade VP at 20' Spacing, Add in No Right Turn Signs at Driveways on Northside and to Side streets on South side.
Plan #1 Phase 1 - Add Pedestrian Crossing Signs at side roads and driveway. Review for STOP sign placement as part of the ADA detour route