Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TR-ROW-0324-00292
Parcel: 14111459B

Review Status: Requires Resubmit

Review Details: RIGHT-OF-WAY REVIEW v.1

Permit Number - TR-ROW-0324-00292
Review Name: RIGHT-OF-WAY REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/19/2024 ROW Engineering Review REQUIRES RESUBMIT 1. The "Reasonable Alternative" lane for cyclists is insufficient. 2.4 Ft is not wide enough. A typical bike lane is 5' wide. A 5' width needs to be maintained through the work area. Show this on the TCP

2. Add a "bike lane taper" at the beginning of the closure. 75'

3. Add a bike detour sign. "M4-9c" sign at the beginning of the lane closure.
03/15/2024 Transportation Application Review REVIEW COMPLETED