Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: TP-PRE-1222-00050
Parcel: 10821328B

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-1222-00050
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED Buildings exceeding 30’ shall be provided with aerial access meeting IFC 2018, Appendix D, Section D105. D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15’ and not greater than 30’ from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which aerial apparatus access road positioned shall be approved by the fire code official.
F.D.C. shall face the street side of the building, IFC 2018, Chapter 9, Section 912, 912.2.1 and shall not be obstructed by a gate
Questions:
Jennifer Peel-Davis
Tucson Fire Department
Fire Plans Examiner
Fire Inspector I, II and Fire Alarm Plans Examiner
Jennifer.Peel-Davis@Tucsonaz.gov
Desk: 520-837-7033
Site Engineering REVIEW COMPLETED Engineering has no comment
Scott Haseman
scott.haseman@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL

PROJECT: HYBRID SCHOOL
ACTIVITY NO. TP-PRE-1122-00050
ADDRESS/PARCEL: 1760 E RIVER RD SUITE 150/108-21-328B
ZONING: C-1

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting.
The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to assure compliance with the applicable UDC development criteria and Technical Standards.

COMMENTS:

1. Landscape/NPPO has no comments on this project.
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Loran Shamis; Lead Planner

PROJECT: Thursday Pre-submittal meeting – TP-PRE-1222-00050 – Fusion Academy
Address: 1760 E River Rd
Parcel(s): 10821328B
Zoning: C-1, MH-1, R-3
Existing Use: Administrative and Professional Offices
Proposed Use: Educational Use – Elementary and Secondary

TRANSMITTAL DATE: January 5, 2023

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package. Development/Occupancy can be phased but the site will need to comply with the applicable UDC standards at each phase.

2. The site is zoned C-1 and the proposed use, Elementary and Secondary Education, is permitted (through a special exception procedure) subject to use specific standards 4.9.3.D.1 - .7 and 4.9.13.O (Table 4.8-4).
a. 4.9.3.D.6 Building Setback – The minimum building setback from all property lines adjacent to R-3 or more restrictive zoning is 20 feet
b. 4.9.3.D.7 – Passenger drop off parking areas shall be provided at a ratio of one motor vehicle parking space (parallel) for every 20 students for which the school if authorized, up to eight spaces. These are in addition to the required off-street parking spaces.

3. Ensure the parking is met for the proposed use and the existing uses. The parking ratio for educational use
a. Grades K – 8 is 1 space per 10 students plus 1 space per 300 square feet of floor area in office use
b. Grades 9 – 12 is 1 space per 5 students.

4. The bicycle parking ratio for educational uses grades K-12
a. Short-term – 1 space per 20 students of planned capacity and a minimum of 2
b. Long-term – 1 space per 10 employees plus 1 space per 20 students of planned capacity. Minimum requirement is 2.

5. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov.
Traffic Engineering Review REVIEW COMPLETED No Comments
TW Hydraulic Modeling Review REVIEW COMPLETED 1. Tucson Water has no comments on, or objections to, the proposed development.
2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov