Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0424-00104
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
Fire New Construction | REVIEW COMPLETED | TP-PRE-0424-00104 • Pre-Application Conference Review v1 • 7333 E ROSEWOOD ST TUCSON, AZ 85710: Based on the information provided, TFD has the following comments: 1. Provide Knox key box(es) under 2018 IFC, 506 2. Provide/maintain fire sprinkler systems following 2018 IFC, 903 3. Provide/maintain fire alarm systems per 2018 IFC, 907 Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
ROW Engineering Review | REVIEW COMPLETED | No Comments David Stiffey David.Stiffey@tucsonaz.gov |
|||
Site Engineering | REVIEW COMPLETED | 1. Site Engineering has no objections or comments to the proposed plans. Mike Ortiz michael.ortiz@tucsonaz.gov |
|||
Site Landscape | REVIEW COMPLETED | Landscape/NPPO have no comments or concerns with the building and dock expansion. Chad Keller chad.keller@tucsonaz.gov |
|||
Site Zoning | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Nicholas Martell, Principal Planner PROJECT: Thursday Pre-submittal meeting - TP-PRE-0424-00104 Address: 7333 E ROSEWOOD ST Zoning: PAD-3 Existing Use: Commercial-Administrative and Professional Office Proposed Use: Commercial-Administrative and Professional Office TRANSMITTAL DATE: May 8, 2024 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The project appears to be in Planning Area 2 of the PAD 3. An Administrative Office use is allowed in Planning Area 2 of PAD 3. 4. Please refer to page 39 of the PAD document for development standards: a. The minimum building setback from public or private streets is a distance equal to 60% of the building height, but no less than 20 feet. b. The maximum floor area ratio is 1.0. c. The maximum building coverage is 90% at ground level and 60% above ground level. 5. Parking is calculated as follows (Table 7.4.4-1 UDC); 1 space per 300 sq. ft. GFA. 6. Provide an expansion calculation to determine whether the site will be required to be brought up to full code compliance. Per UDC 7.4.3.E.1” If an expansion is less than 25% or if a series of expansions cumulatively results in less than a 25% expansion in floor area, the requirements of this section apply only to the proposed expansion. Existing development on the site is subject to the zoning regulations in effect at the time of approval of the most recent approved plan for the existing development.” 7. Ensure compliance with UDC 7.5 regarding off-street loading: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5796 8. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions about this transmittal, contact me at Nicholas.Martell@tucsonaz.gov |
|||
TW New Area Development | REVIEW COMPLETED | TP-PRE-0424-00104 - Pre-Application Conference Review v1 – 7333 E ROSEWOOD ST Tucson Water has no objections to, or comments on, the proposed development. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |