Plan Review Detail
Review Status: Approved
Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1
Plan Number - TP-PRE-0326-00056
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Fire New Construction * | REVIEW COMPLETED | TP-PRE-0326-00056 • Pre-Application Conference Review v1 • 700 E BROADWAY BL TUCSON, AZ 85719: Based on the information provided, TFD has no comments at this time. Questions: patricia.shelton@tucsonaz.gov / 520.837.7082 |
|||
| ROW Engineering Review * | REVIEW COMPLETED | No comments | |||
| Site Engineering * | REVIEW COMPLETED | Permit Activity Number: TP-PRE-0326-00056 Project: Parking Lot Location: 700 E BROADWAY BL Review Date: 04/01/2026 *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.* City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: Site engineering has no comments. This review is for Pre-Application purposes. Please be aware that additional comments may be forthcoming during submission process. If you have any questions or concerns, please contact Joe Macaulay at Joe.Macaulay@tucsonaz.gov. |
|||
| Site Landscape * | REVIEW COMPLETED | PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, PLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: SITE PLAN FOR PARKING REVIEW ACTIVITY NO: TP-PRE-0326-00056 ADDRESS: 700 E BROADWAY BL ZONING: LIGHT INDUSTRIAL ZONE (I-1) LAND USE: PARKING 2026.04.01 THE COMMENTS PROVIDED ARE PRELIMINARY AND ARE NOT TO BE ASSUMED AS A COMPLETE REVIEW OF THE PROPOSAL. DURING THE DEVELOPMENT PACKAGE REVIEW PROCESS, A FULL REVIEW WILL BE MADE BY THE SITE LANDSCAPE/NPPO REVIEW SECTION TO ENSURE COMPLIANCE WITH THE APPLICABLE CITY OF TUCSON UNIFIED DEVELOPMENT CODE, TECHNICAL STANDARDS MANUAL AND ADMINISTRATIVE MANUAL REQUIREMENTS FOR SITE LANDSCAPE, NATIVE PLANTS AND RAINWATER HARVESTING. SITE LANDSCAPE/NPPO COMMENTS: 1. Site landscape has no comments or concerns with this parking area. Thank you. Chad Keller, PLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
|||
| Site Zoning * | REVIEW COMPLETED | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Krista Hansen, Lead Planner PROJECT: Pre-submittal meeting TP-PRE-0326-00056 Parcel: 12407179C, 12410005J Address: 700 E BROADWAY BL Zoning: C-3 / I-1, Sunshine Mile UOD / UOD-3, Euclid Subarea Use: Educational - Instructional School; Commercial Services - Administrative and Professional Office TRANSMITTAL DATE: April 2, 2026 COMMENTS: 1. Any proposed development must comply with the City of Tucson Unified Development Code (UDC) Administrative Manual Chapter 2-06 – Development Package (DP). Building permits can be submitted and reviewed concurrently with the development package but the building plans cannot be approved until the development package is approved and the building plans are reviewed for consistency. 2. The site is zoned C-3 and I-1. It is located within the Sunshine Mile District (SMD) – Euclid Subarea optional overlay. a. Instructional School is permitted in C-3 and I-1. b. Administrative and Professional Office is permitted in C-3 and I-1 (subject to UDC 4.9.13.Q). 3. Motor Vehicle parking ratios (UDC Table 7.4.4-1) a. Instructional School – 1 space per 200 sq ft GFA b. Admin and Professional Office – 1 space per 300 sq ft GFA 4. The last approved permit for the building, TC-COM-0125-00208, was a tenant improvement for the first floor only (9,353 sq ft). Clarify if the Use is Instructional School or Medical Services – Outpatient. If the offices (on the first floor) are used by the Instructional School / Resilient Health, the Use is considered Instructional School, and the entire 1st floor GFA needs to be included in the Instructional School parking calculation (1 space per 200 sq ft). If there are two separate Uses on the first floor – clearly indicate that on the site plan. 5. If the 1st floor is an Instructional School (9,353 sq ft), and the 2nd floor is Administrative Offices (11,427 sq ft), 86 parking spaces are required (39 for Office and 47 for Instructional School). 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at krista.hansen@tucsonaz.gov. |
|||
| TW New Area Development * | REVIEW COMPLETED | Based on the information provided, Tucson Water has no concerns with the development. The building is currently served by an existing 2-inch potable water meter, one fire hydrant and one existing fire service connection available on site. All tied into an 8-inch PVC water main (A zone). Water pressure in this area is 41-48 PSI at an elevation of 2398ft. Water pressure can vary by an additional 5 psi +/-. If any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to Kathryn Gerber (Engineering Manager) at Kathryn.Gerber@tucsonaz.gov. |