Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: TP-PRE-0325-00050
Parcel: 11811015M

Address: Unknown

Review Status: Approved

Review Details: PRE-APPLICATION CONFERENCE REVIEW v.1

Plan Number - TP-PRE-0325-00050
Review Name: PRE-APPLICATION CONFERENCE REVIEW v.1
Review Status: Approved
Review Date Reviewer's Name Type of Review Description Status Comments
Fire New Construction REVIEW COMPLETED TP-PRE-0325-00050 • Pre-Application Conference Review v1 • W. Silverlake Rd. & S. Fiandaca Blvd.:
Based on the information provided, TFD has the following comments:
1. Verify hydrant coverage. IFC 24, 507.5.1 (appears additional hydrant will be
required)
Questions: patricia.shelton@tucsonaz.gov / 520.837.7082
ROW Engineering Review REVIEW COMPLETED TP-PRE-0325-00050 – Fiandaca Bl

1. The owners of the utilities proposed within the public rights-of-way need to have a utility franchise license with the city.

2. Pavement repairs shall be in accordance with the City of Tucson Public Utility Administrative Manual.

3. A Flood Plain Use Permit will be required for the Greyhound Wash crossing.

If you have any questions, please contact Richard Leigh at Richard Leigh at richard.leigh@tucsonaz.gov
Site Engineering REVIEW COMPLETED TP-PRE-0325-00050
11811015L

1. Show all dimensions and limits of work for PAAL, parking spaces, sidewalks, etc.
2. Please include area of disturbance and cut/fill quantities on the plan set.
3. Provide pedestrian circulation in accordance with TSM 7-01.3 and 7-01.4.
4. The Greyhound Wash, a COT floodplain, passes through the north portion of the property. Please show the delineated floodplain on site plans.

Chris Arrington
chris.arrington@tucsonaz.gov
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: RECONFIGURE PARKING AREA FOR EV CHARGER INSTALL AND AUTOMATED VEHICLE INSPECTION BUILDING
ACTIVITY NO: TP-PRE-0325-00050
PARCEL: 11811015L
ZONING: I-1 LIGHT INDUSTRIAL ZONE

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Landscape/NPPO to ensure compliance with the applicable UDC development criteria and Technical Standards.

SITE LANDSCAPE/NPPO COMMENTS:

1. A landscape plan is required per UDC 7.6.2.B.1-b. The Unified Development Code requires all new development, or an expansion of greater than 25% of an existing development to submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4 and Administrative Manual 2-10.

2. This reconfiguration of the parking area indicates the removal of existing parking lot planting islands and salvaging the plants for reuse on site. With the new parking layout provide the required number of trees in the vehicular use area (1 tree to 4 parking spaces) per UDC 7.6.4.B.1. Trees are to be distributed evenly throughout the parking lot, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

3. In general, to the greatest extent possible, grade the new asphalt paving areas toward the proposed reconfigured landscape areas to maximize rainwater harvesting. Depress the proposed landscape areas 6-9” and provide curb cut inlets and outlets.

4. At the west parking area, a new landscape planting area is proposed adjacent to an existing street landscape border that is providing rainwater harvesting. Make sure that this landscape areas is depressed for water harvesting and that it ties in seamlessly the existing street landscape border along S Fiandaca Bl. Same comment for the east parking lot area.

5. The proposed AVI building is shown in a landscape area that appears to be depressed for water harvesting. Provide a 1:1 mitigation for any lost plant material in this area and show the revised drainage pattern from the building footprint encroachment within the depressed landscape area.

6. A drip irrigation plan and details are required for all proposed landscape planting areas.

7. DTM review is required for all planting and irrigation in the ROW prior to the approval of the development package. Reach out to David Marhefka (david.marhefka@tucsonaz.gov) if necessary for this project.

8. All landscape plans shall incorporate water conserving design as defined in UDC Section 7.6.6, Use of Water, and as described in the Technical Standards Manual 5.01-5.11.

9. Coordinate the Landscape Plan and the Civil Grading Plan to include rainwater harvesting that show identical basin size, grades, spot elevations and curb cut locations.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
Site Zoning REVIEW COMPLETED CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington, Planner

Parcel(s): 118-11-015L
Zoning: I-1
Existing Use: Transportation Service, Land Carrier
Proposed Use: Transportation Service, Land Carrier
TRANSMITTAL DATE: 3/27/25

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 – Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved. Each lot (Lot 2 & Lot 3) must have its own development package submitted.
2. The existing zone is I-1. Transportation Service, Land Carrier is a permitted use in the I-1 zone, subject to Use-Specific Standard 4.9.13.Q.
3. Update parking calculations on DP18-0235.
4. Setbacks:
Front Street: 20’
Side/Rear: 0’
5. Parking Area Access Lanes (PAAL) shall be 24 feet wide for 2-way traffic and fire access.

6. Comply with Section 7-01 Pedestrian Access in the Technical Standards Manual for new construction.


7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov.
TW New Area Development REVIEW COMPLETED TP-PRE-0325-00050 - Pre-Application Conference Review v1 – APN’s 11811015L and 11811015M - 1,800 S.F. Automated Vehicle Inspection Bldg.

1. Please accept Tucson Water’s and my personal apologies for not being able to attend this meeting.

2. There is an existing 6” public water main in S. Finandaca Blvd. that can provide potable water to this project. See Tucson Water’s SE231413 valve map for more information about this water main. Copies of any valve map(s) and/or ‘as-built’ plan(s) referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov.

3. No new connections to Tucson Water’s distribution system have been shown on the submitted plans. This causes me to have the following questions about this project:
a. Will the automated vehicle inspection building require water service?
b. And will a source of water be needed for the concrete washpit?

4. Please e-mail the answers to the above questions (and ask any questions you may have) to me. My e-mail address is tim.rowe@tucsonaz.gov.

5. If and when any new domestic water, irrigation water, or fire water services are needed to serve this proposed development, please contact Tucson Water’s New Services Section by calling 520-791-5164 or by sending an email to TW_Common@tucsonaz.gov.

The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:


Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov