Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-1223-00497
Parcel: 14019017A

Address:
839 E MINORKA RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.5

Permit Number - TD-DEV-1223-00497
Review Name: DEVELOPMENT PACKAGE NEW v.5
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/29/2024 Site Engineering APPROVED City of Tucson code does not designate the option to ignore handrail requirements in non-public areas. Be prepared to provide handrail during construction as a requirement during inspection.
Joshua Garcia
joshua.garcia@tucsonaz.gov
08/02/2024 CDRC Post Review Express PENDING ASSIGNMENT
08/02/2024 Commercial Plumbing REQUIRES RESUBMIT The ambiguous note is still in place and the cleanout spacing in one section of the building sewer is over 101 feet of horizontal distance. Cleanouts shall be located at intervals of not more than 100-feet apart, measured along the developed pipe length from the upstream entrance of the cleanout. [Second comment: The note, “PROVIDE CO EVERY 100 [feet]” is ambiguous because it does not indicate that the spacing of the cleanouts is based on the developed pipe length.] [ Initial comment: Building sewers smaller than 8-inches shall have cleanouts located at intervals of not more than 100-feet apart, measured along the developed pipe length from the upstream entrance of the cleanout. Reference: Section 708.1.2, IPC 2018.
07/03/2024 CDRC Application Completeness Express REVIEW COMPLETED