Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-1223-00493
Parcel: 14139030A

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-1223-00493
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
10/22/2024 ROW Engineering Review APPROVED
N/A CDRC Post Review PENDING ASSIGNMENT
N/A External Reviewers - Pima County Addressing PENDING ASSIGNMENT
N/A NPPO PENDING ASSIGNMENT
N/A Site Engineering PENDING ASSIGNMENT
N/A Site Landscape PENDING ASSIGNMENT
N/A Site Zoning PENDING ASSIGNMENT
11/18/2024 Commercial Plumbing REQUIRES RESUBMIT With the new manhole rim and finish floor elevations, Lots 8 and 9 will not require the addition of backwater valves but lot 13 will require the addition of a backwater valve. [Initial comment: Based on an assumed FFE 8 inches above the proposed pad elevation, the following additional lots will require backwater valves because the rim elevation of the next upstream sanitary manhole is less than 12” below the FFE: 2, 5, 6, 16, 25, 30, 31, 33, 38, and 43. Reference: Section 714.1, IPC 2018, as amended by the City of Tucson.]