Permit Number: TD-DEV-1124-00312
Parcel: 141010130

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-1124-00312
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/31/2024 NPPO APPROVED
12/31/2024 Site Landscape APPROVED
01/17/2025 CDRC Post Review Express PENDING ASSIGNMENT
12/30/2024 ROW Engineering Review REQUIRES RESUBMIT TD-DEV-1124-00312 • 7405 S PASEO GRAN ESCALERA
1. Per Sec. 2-01.9.2 and 9.3, cut and fill slope shall be set back from the property boundary a minimum of 2 ft.
2. The subdivision proposed public roadway improvements will have to be constructed under a Private Improvement Agreement (PIA). For additional information on PIAs please visit https://www.tucsonaz.gov/tdot/private-improvement-agreement or contact Jesus Villezcas (jesus.Villezacas@Tucsonaz.gov) or at 520-791-5100.

If you have any questions, please contact Richard Leigh at richard.leigh@tucsonaz.gov.
12/27/2024 Site Engineering REQUIRES RESUBMIT 1. Add TD-DEV-1124-00312 to the plan set.
2. Provide a detail with specs for the retaining walls that will be followed as a baseline design. Please confirm that the list of retaining walls provided meets this criteria: the retaining walls will exceed 4ft from the bottom of the footing to the top of the wall. If not, please provide this additional list or mark these walls with an asterisk or similar. Add "by separate permit" to this list. Each contiguous retaining wall can be applied for as one wall under one wall permit. Please calculate how many contiguous retaining walls are proposed.
3. The proposed drainage basin slope stabilization - dumped rock riprap on filter fabric for 2:1 side slopes - does not meet the requirements of DSSDR 4.7.1. Slopes no steeper than 2:1 require hand-placed riprap over filter fabric. In areas steeper than this, the riprap will need to be grouted. Please revise. Additionally, label all side slopes on all drainage basin on the grading sheets.
4. The SWPPP does not show erosion control around the grading limits. It only shows it on half of the project. Erosion control is required around the entire grading limits on all sides. Please revise.

Mike Ortiz
michael.ortiz@tucsonaz.gov
01/06/2025 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: La Escalera Phase 4, Lots 1-215
PRIVATE GRADING & DRAINAGE PLAN (1st Review)
TD-DEV-1124-00312

TRANSMITTAL DATE: January 6, 2025

DUE DATE: December 27, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is December 04, 2025.

CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-1124-00312, adjacent to the title block on all sheets.

Additional comments:

2. COMMENT: - Until approved by all review agencies Zoning cannot approve the grading plan.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
11/27/2024 CDRC Application Completeness Express REVIEW COMPLETED
12/23/2024 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added TEP to the workflow. Review request email sent to TEP.
12/30/2024 Commercial Plumbing REVIEW COMPLETED
01/17/2025 External Reviewers - Tucson Electric Power (TEP) REVIEW COMPLETED Greetings,

We would like to express our gratitude for your commitment to safety and for partnering with us. Tucson Electric Power Co. (TEP) values the collaboration as we endeavor to facilitate new developments within our service area.

After a thorough review, TEP has assessed the development plans TD-DEV-1124-00312 and has no objections to the proposed designs. Please be advised that any removal or relocation of existing TEP facilities will be the financial responsibility of the developer. If modifications to the preliminary design concerning TEP facilities are necessary, such revisions will be formalized through a separate agreement.

Thank you for your cooperation and understanding.

Respectfully,
Tucson Electric Power Co.
Land Resources Department
12/26/2024 Fire New Construction REVIEW COMPLETED
12/09/2024 OK to Submit - Engineering Fast REVIEW COMPLETED
12/20/2024 OK to Submit - Zoning Fast REVIEW COMPLETED
12/24/2024 ROW Review REVIEW COMPLETED