Permit Number: TD-DEV-1025-00262
Parcel: 10714374A

Address:
401 E GRANT RD

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-1025-00262
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Fire New Construction Standard PENDING ASSIGNMENT
N/A NPPO Standard PENDING ASSIGNMENT
N/A Site Landscape Standard PENDING ASSIGNMENT
N/A Site Zoning Standard PENDING ASSIGNMENT
02/23/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-1025-00262 (1st Review)
Project: Development Package for the Frys #20 Fuel Center.
Location: 401 E GRANT RD
Review Date: 2/23/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0126-00004, adjacent to the title block on all sheets.
2. Pedestrian circulation - A sidewalk is required adjacent and parallel to any access lane or PAAL on the side where buildings are located TSM7-01.4.1.B and Sidewalks must connect all areas of the development TSM 7-01.4.1.D This will need to be addressed for all buildings
3. Demonstrate how roof drainage will be managed so as to remain compliant with TSM 7-01.4.3.E
4. Provide dimensions for the vehicle area at the entrance off of Grant RD. Due to Grant RD being designated as an Arterial Street, vehicle maneuverability must be shown to demonstrate how a vehicle who attempts to use the access off Grant RD can turn around onsite without having to back up into Grant RD ROW. City of Tucson 5.11 Access Management Guidelines
5. Referring to the parking calculations, I can not find where the ADA parking spot is being proposed. Revise accordingly
a. Ensure to include construction details for the ADA sign and parking
6. The waste stream calculations refer to a 2 CY container, but the container nor the trash enclosure are not shown on the site plan. Revise to show the location of the trash enclosure.
a. Provide trash enclosure details in compliance with TSM 8-01.5.0 It’s encouraged to use the figures presented in TSM 8-01.9.0 for minimum basis for details for the Dumpster layout shown.
7. Provide dimensions to parking spaces on the site plan.
8. Revise general note #7 to the Zoning and Land Use General Note: “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2
9. Revise the sheet index to reflect all development package pages/sheets.
a. This should be done for the bottom corner sheet xx of xx as well.
10. The architect stamp from Robert P. Johnson appears to be distorted. For resubmission, it will be required that a new stamp be placed on the plan set. It must be dated accordingly.
11. Show that this project falls in compliance with 8-01.5.1.A by providing the possible space for solid waste and recycling collection services.
12. Pedestrian circulation is required to connect all buildings, dumpster areas, common areas, and the sidewalk on all the street frontages per TSM 7-01.3.3. Demonstrate how this requirement is addressed for connecting to frontage road to the West & South. This will need to be shown for the ADA parking space and bicycle parking as well.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
02/20/2026 CDRC Review Coordinator Express REVIEW COMPLETED NO EXTERNAL REVIEWERS
External Reviewers not required. No further action is required from the customer at this time.
03/12/2026 Commercial Plumbing Standard REVIEW COMPLETED
02/20/2026 OK to Submit - Zoning Fast REVIEW COMPLETED
03/10/2026 ROW Engineering Review Standard REVIEW COMPLETED