Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.3
Permit Number - TD-DEV-1023-00417
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/14/2023 | Commercial Plumbing | APPROVED | The rim elevation of the next upstream sanitary manhole (8656*05, 2389.6’) is more than 12”below the first floor elevation (2392’). A backwater valve shall not be installed per Section 714.1, IPC 2018, as amended by the City of Tucson. [Initial Comment: Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve for the proposed building per Section 714.1, IPC 2018, as amended by the City of Tucson.] | ||
| 12/14/2023 | Site Zoning | APPROVED | |||
| 12/14/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 12/06/2023 | CDRC Application Completeness Express | REVIEW COMPLETED |