Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-1023-00417
Parcel: 115043060

Address:
1131 N 6TH AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-1023-00417
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/14/2023 Commercial Plumbing APPROVED The rim elevation of the next upstream sanitary manhole (8656*05, 2389.6’) is more than 12”below the first floor elevation (2392’). A backwater valve shall not be installed per Section 714.1, IPC 2018, as amended by the City of Tucson. [Initial Comment: Provide the rim elevation of the next upstream sanitary manhole. Determine the need for a backwater valve for the proposed building per Section 714.1, IPC 2018, as amended by the City of Tucson.]
12/14/2023 Site Zoning APPROVED
12/14/2023 CDRC Post Review Express PENDING ASSIGNMENT
12/06/2023 CDRC Application Completeness Express REVIEW COMPLETED