Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - TD-DEV-0925-00234
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/06/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0925-00234 (REV 1st Review) Project: Rev 3 - Update to west side path, NW & SW bollards, started 06.25.2026 Rev 2 - update to water basins, curb line, slab, started 01.23.2026 ** Rev 1 - Started 12.10.2025, update to downspout locations ** Minor Development Package for added square footage to building, no additional site work. Location: 2884 E GANLEY RD Review Date: 7/6/2026 Reviewer: Marco Contreras – Engineering Associate & Joe Macaulay – Civil Engineer Reviewer Contact Information: marco.contreras@tucsonaz.gov & Joe.Macaulay@tucsonaz.gov Related cases: Plan review for the above-referenced development package has been completed. This review was conducted for compliance with applicable development criteria including the City of Tucson Unified Development Code (UDC), Administrative Manual (AM) Section 2-6, and Technical Standards Manual (TSM) sections governing waste management, pedestrian access, hydrology – retention/detention requirements, and all applicable site standards. The following comments must be addressed prior to approval. To help facilitate a timely resubmittal, please provide updated plans and calculations along with a written response to each comment, indicating what action was taken and where the change can be found on the plans. Do not use revision clouds on resubmittal drawings — clouds are reserved for post-permit revisions only. Submit your response letter and updated plan set & reports as separate files. Applicable Code Links for quick/direct reference: City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf City of Tucson Chapter 25: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-18593 Site Engineering Grading Review Comments: 1. Revise plan view (sheet 2) to provide an official keynote/call-out for the proposed bollards as discussed in the narrative letter. The keynotes should explicitly show where the bollards are to be proposed. 2. It will be required that two bollards be placed at the SE corner – one bollard on the Eastern corner and one bollard at the Southern Corner. 3. Provide dimensions to the setback distance between the new bollards and the proposed expansion/addition. The required minimum clearance will be 2 feet. [UDC 7.4.6.F.2.b] |
||
| 06/25/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 07/02/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | |||
| 06/25/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 06/29/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |