Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0925-00234
Parcel: 140270490

Address:
2884 E GANLEY RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0925-00234
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/21/2025 NPPO Standard NOT REQUIRED
10/21/2025 Site Landscape Standard NOT REQUIRED
10/06/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-0925-00234
Location: 2884 E GANLEY RD
Review Date: 10/6/2025

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Manual (TM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code.
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf


Site Engineering Comments:
1. Provide the development package activity number TD-DEV-0925-00234 on the plans.
2. Due to the proposed expansion is over 2,000 sq feet of impervious and disturbed area, first flush will be required. Design Standards for stormwater detention and retention. 2.1.2.b
3. A drainage statement will be required to show compliance with meeting the expansions first flush requirements. DSSDR chapters 2 & 3.
4. Provide total acres of disturbance as well as any potential cut/fill quantities.
5. Provide updated waste stream calculations with the additional sq footage factored in. TSM 8-01.8.0


If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
10/24/2025 Site Zoning Standard REQUIRES RESUBMIT CDRC TRANSMITTAL

TO: Development Services Department
Plans Coordination Office

FROM: Loran Shamis
PDSD Zoning Review Section

PROJECT: Building addition
Development Package (1st Review)
TD-DEV-025-00234 (2884 E Ganley Rd)

TRANSMITTAL DATE: October 24, 2025
DUE DATE: October 14, 2025

COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is September 17, 2026.

SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS)

2-06.4.0 CONTENT REQUIREMENTS

1. COMMENT: 2-06.4.3 - Provide the development package case number, TD-DEV-025-00234, adjacent to the title block on each sheet.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

Zoning and Land Use Notes

2. COMMENT: 2-06.4.7.A.4 – Per UDC Table 4.8-5, Commercial Storage in I-1 is permitted subject to use specific standards 4.9.10.A and 4.9.13.Q. Include these use specific standards in the Zoning and Land Use Notes.

2-06.4.7.A.8 - For development package documents provide:

3. COMMENT: 2-06.4.7.A.8.c – The expansion calculation is incorrect. An expansion of 5,360 square feet of 30,000 square feet results in 17.9% expansion. Please correct.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. COMMENT: 2-06.4.9.H.5 – Correct the parking ratio for Manufacturing Use in the Vehicle Parking calculation. The calculation currently states the parking ratio is 1 space to 300 square feet of gross floor area but applies 1 space to 1,000 sf gfa. Per UDC 7.4.4-1, General Manufacturing requires 1 space per 1,000 square feet of gross floor area.

5. COMMENT: 2-06.4.9.H.5 – Dimension the PAAL adjacent to the addition on the west side of the building. Per UDC 7.4.6.F.b, access lanes and PAAL must be setback 2’ from any wall, screen, or other obstruction over six inches. Demonstrate compliance with this standard.

6. COMMENT: 2-06.4.9.Q – Include the proposed height of the addition in the building footprint.


***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations


If you have any questions about this transmittal, Contact Loran Shamis by email Loran.Shamis@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home.
Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf.
09/23/2025 CDRC Review Coordinator Express REVIEW COMPLETED EXTERNAL REVIEWERS
CDRC added, TAA,, SWG USPS, and PAG to the workflow. Review request email sent to TAA, FYI email sent to, SWG USPS PAG.
10/13/2025 Commercial Plumbing Standard REVIEW COMPLETED
09/23/2025 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
09/23/2025 External Reviewers - Southwest Gas Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
10/06/2025 External Reviewers - Tucson Airport Authority Standard REVIEW COMPLETED October 3, 2025
Planning and Development Services
City of Tucson
201 North Stone Avenue
Tucson, AZ. 85701
RE: TD-DEV-0925-00234, 1st Submittal, Minor Development Package for added square footage
to building, no additional site work. / 2884 E. Ganley Rd, Tucson, AZ. 85706, Received
September 23, 2025
To whom this may concern,
Thank you for the opportunity to comment on TD-DEV-0925-00234, 1st Submittal, a
development plan additional square footage added to an existing building at 2884 East Fanley
Road. This development is located in the N.E. quarter of the S.E. quarter of Section 8,
Township 15S, Range 14E, of the Gila and Salt River Meridian. The development site occupies
parcel number 140-27-0490, covers approximately 4.34 ± acres, and is zoned as Light Industrial
Zone (I-1). The nearest major roadway intersection is East Ganley Road and South Country
Club Road, approximately 675 feet to the northeast of the subject development.
This site does lie within the Tucson International Airport avigation easement requirements and
public disclosure area, FAA traffic pattern airspace, FAA Part 77 airspace, City of Tucson
Airport Environs Overlay Zone – Height Zone 100-120 Feet, City of Tucson Airport Environs
Overlay Zone – Airport Hazard Districts, and City of Tucson Airport Environs Overlay Zone –
Compatible Use Zone 2.
Below are the responses the FAA Pre-Screening Tool generated for this project:
1. Based on the information you provided, you are required to file notice with the FAA. You
must submit notice at least 45 days before the start of the proposed construction or
alteration or the date an application for a construction permit is filed, whichever is
earliest.
2. Note: If you propose construction or alteration that is subject to the licensing
requirements of the Federal Communications Commission (FCC), you must submit
notice to the FAA on or before the date that an application is filed with the FCC. Visit
FCC Licensing to learn more.
These conditions must be included in the plan documents and shall be identified in the general
notes section of all future plans submitted to the City of Tucson for review.
1. “According to the Federal Aviation Administration (FAA) Pre-Screening Tool, this project
area is located on an airport. As this project develops, all applicants must file FAA Form
7460 with the FAA at least 45 days before construction activities begin unless FAA staff,
with the Obstruction Evaluation / Airport Airspace Analysis (OE/AAA), provides the
project applicant with written communication that filing FAA Form 7460 is not required. It
is highly recommended that the applicant file earlier than 45 days to provide the
applicant with sufficient time to respond to any concerns identified by the FAA. Note also
that cranes to be used during all development or construction activities must also be
identified with Form 7460. Please file Form 7460 at
https://oeaaa.faa.gov/oeaaa/external/portal.jsp.”
2. “Development of the subject property shall not cause or potentially affect aviation in the
vicinity of the site, determined in the reasonable judgment of the Tucson Airport
Authority, including but not limited to, physical obstructions to aircraft operations,
interference with operations by way of electrical static, visual obstructions through
emissions or glare, and/or the open storage of petroleum products, explosive materials,
or materials which attract or lead to the concentration of wildlife.”
Although this project does not propose a change in plan designation or zoning the Tucson
Airport Authority highly recommends the applicant add the following notes into the general notes
of the revised development plan. This project is located approximately 3,600 feet northeast of
Tucson International Airport and is within FAA traffic pattern airspace, an area which would be
subject to aircraft overflight and noise due to being in close proximity to Tucson International
Airport.
The proposed notes would provide a means of assuring that future owners and tenants of the
property are aware they are in proximity an airport and further assures the continued right of the
City of Tucson, Tucson Airport Authority, and all persons lawfully utilizing the Tucson
International Airport the right to utilize the airspace above or near the property. This would be
accomplished through the property owner recording the Avigation Easement and providing the
Airport Disclosure Statement to the new residents of all residential uses. The Tucson Airport
Authority believes the proposed note helps to support the City of Tucson Airport Environs
Overlay Zone and supports Plan Tucson – Regional and Global Positioning policy 4 (RG-4).
1. "That prior to the City's approval of the proposed development, the property owner must
record the Avigation Easement that discloses the existence and operational
characteristics of the Tucson International Airport to future owners or tenants of the
property and further conveys the right to the public to lawfully use the airspace above the
property. The Avigation Easement shall be recorded in a manner with the Pima County
recorder which shall document it as having title liability. The content of such documents
shall be according to the form and instructions provided.”
The current property owner or person authorized to sign on behalf of the current property
owner must complete, sign, and record the Avigation Easement. Please record the
Avigation Easement with the Pima County Recorder’s Office. Then send a complete
copy of the recorded easement document to Tucson Airport Authority by either email
(send to srobidoux@flytucson.com) or to the mailing address provided below.
Scott Robidoux
Manager of Planning
Tucson Airport Authority
7250 South Tucson Blvd, Suite 300
Tucson, AZ 85756”
2. Applicable to residential uses only
“The property owner/developer/applicant must provide the Airport Disclosure Statement
form, at time of sale, to the new property owners with all new unit purchases. In the
event the development of any residential uses does not involve the sale of new units but
is instead offering rental residential units to the public, the new tenant of the rental unit
must be provided a copy of the Airport Disclosure Statement form. The intent of the
Airport Disclosure Statement form is to educate and notify the new residents that they
are living near an airport. The content of such documents shall be according to the form
and instructions provided.”
The property owner (for itself or its tenants) shall forward a signed copy of the Airport
Disclosure Statement form to the Tucson Airport Authority within ten (10) days of
signature, using the Scott Robidoux mailing address provided above.
Please do not hesitate to contact me if you have any questions or concerns regarding this
comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-
573-4811.
Respectfully,
Scott Robidoux, C.M.
Manager of Planning
cc file
09/23/2025 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED FYI
CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
10/09/2025 Fire New Construction Standard REVIEW COMPLETED
09/19/2025 OK to Submit - Zoning Fast REVIEW COMPLETED
09/29/2025 ROW Engineering Review Standard REVIEW COMPLETED ROW improvements not required