Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.3
Permit Number - TD-DEV-0923-00388
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/14/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 11/28/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: United Rentals Development Package (2nd Review) TD-DEV-0923-00388 TRANSMITTAL DATE: November 28, 2023 DUE DATE: December 11, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is October 03, 2024. CONTENT REQUIREMENTS 1. This comment was not fully addressed. Sheet 2 shows 1 of 1 and should be 2 of 5. COMMENT: 2-06.4.2.D – The title block shall include the page number and the total number of pages in the package (i.e., sheet xx of xx). 2. This comment was not fully addressed. The DP case number was not provided on sheet 2. COMMENT: 2-06.4.3 – Provide the development package case number, TD-DEV-0923-00388, adjacent to the title block on all sheets. 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. 2-06.4.7.A - Zoning and Land Use Notes 3. This comment was not fully addressed. Provide the Use Specific Standards, 4.9.9.C and 4.9.13.Q, within Site/Zoning Data note 4. COMMENT: 2-06.4.7.A.4 – Based on the definition of Vehicle Rental and Sales, The sale, lease, and/or rental of automobiles, motorcycles, noncommercial trucks, boats, vans, motor homes, trailers, or other recreational vehicles. Typical uses include automobile and truck dealers and rental agencies, the proposed use is not correct. Following discussion with staff and the Zoning Administrator this use should be considered Heavy Equipment Sales, a use allowed in the I-1 & I-2 zone subject to Use Specific Standard 4.9.9.C and 4.9.13.Q. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 4. As you do not want to combine parcels at a minimum a Covenant Regarding Development and use of Real Property will need to be executed and recorded prior to approval of this DP. Contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov, to obtain a copy of the covenant. COMMENT: 2-06.4.9.B – As this site is made up of five (5) parcels, 101-20-033D, 101-20-033F, 101-20-032C, 101-20-032D & 10120031E, a lot combination is required. Provide a copy of the approved Pima County Assessor’s Office Combo Request form with the next submittal. 5. This comment was not addressed. Provide an approved plan that shows the equipment storage areas. COMMENT: 2-06.4.9.H.5 – As this is an expansion of use area and additional equipment storage area is proposed, clarify how dust control will be provided for the storage areas. Per UDC Article 7.4.6.I.1.d approved by the City Engineer may be required. 6. This comment was clearly addressed. Sheet 3 “SITE LEGEND” note “C” states “STRUCTURE TO BE SAVE AND REUSED ON NEW CONCRETE SLAB”, but you response to comments states “The was bay will be replaced. COMMENT: 2-06.4.9.Q – Clarify if the wash bay building will be replaced or if this will only be a concrete pad without a building or shade cover. If a new building or shade cover is proposed clearly show it on the plan and provide the square footage and height within the footprint. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package & detailed response letter. |
||
| 11/09/2023 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 12/14/2023 | External Reviewers - Arizona Department of Transportation (ADOT) | REVIEW COMPLETED | We appreciate the opportunity to review this submission. ADOT has no comments at this time. Regards, Doug Moseke, PE Assistant District Engineer 1221 S. 2nd Avenue Tucson, Arizona 85713 O: 520.388.4219 C: 520.354.0786 azdot.gov |