Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0824-00238
Parcel: 10509553A

Address:
4888 N STONE AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.3

Permit Number - TD-DEV-0824-00238
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
12/11/2024 Site Engineering APPROVED
12/13/2024 CDRC Post Review PENDING ASSIGNMENT
12/13/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: El Rio Health Rillito Clinic
Development Package (3rd Review)
TD-DEV-0824-00238

TRANSMITTAL DATE: December 13, 2024

DUE DATE: January 07, 2025

COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is , 2025.

2-06.4.7 - General Notes
The following general notes are required. Additional notes specific to each plan are required where applicable.

2-06.4.7.A - Zoning and Land Use Notes

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

1. The PDMR must be approved by all review agencies prior to approval of this DP. Zoning was not able to find a PDMR application with this submittal. COMMENT: 2-06.4.9.H.5.a – Compact vehicle parking spaces are not allowed, and a Parking Design Modification Request (PDMR), UDC Article 7.4.10, will need to be submitted and approve for the reduced width of the proposed vehicle parking spaces. Also, per UDC Article 7.4.10.D.9 The number of parking spaces with decreased dimensions may not exceed 10% of the total number of parking spaces provided. Based on 563 provided vehicle parking spaces you are only allowed 56 compact spaces on this site. A Board of Adjustment for Variance will need to be submitted and approved to all 58 compact spaces.

2. The relocated crosswalk is still within the stacking area of the drive-through. A TSMR will be required to allow the sidewalk within the stacking area of the drive-through. Zoning acknowledges that the crosswalk is not within the required stacking. COMMENT: 2-06.4.9.R – As the drive-through that is proposed on the south elevation of permit TC-COM-1024-02030, was not clearly shown on the DP, the following comment applies. Per TCM Section 7-01.4.1.G Sidewalks or crosswalks cannot cross any type of stacking areas for drive-through lanes. That said the crosswalk shown about midway in the proposed drive-through will need to be relocated.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: A revised development package as well as a comment response letter. To resubmit, visit the Tucson Development Center Online at https://tdc-online.tucsonaz.gov/#/home. The instructions for resubmittal can be found at https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/revisions-and-resubmittals.pdf.
12/06/2024 CDRC Application Completeness REVIEW COMPLETED