Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0824-00237
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
09/19/2024 | CDRC Post Review | PENDING ASSIGNMENT | |||
09/17/2024 | Site Engineering | REQUIRES RESUBMIT | 1. Please include signage at ride share location at North East corner of parking lot. 2. Please include additional bollards at muster area and building exit on north side of parking lot per TSM 7-01.3.4.2.B 3. Please provide additional signage on Alvernon outlining "No Truck Traffic" "Amazon Only" Joshua Garcia joshua.garcia@tucsonaz.gov |
||
09/12/2024 | Site Zoning | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Loran Shamis, Project Manager PDSD Zoning Review Section PROJECT: TD-DEV-0824-00237 (3780 E Valencia Rd) 1. COMMENT: Please provide an updated parking calculation that demonstrates the required minimum parking and the provided parking. Include ADA accessible van and standard parking minimum required and provided. The minimum parking ratio required is 1 space per 5,000 square feet of gross floor area. Per the gross floor area on last approved development package, the required ADA accessible parking is 9 ADA accessible standard parking spaces and 2 ADA accessible van parking. 2. COMMENT: On the enlarged site plan on Sheet AS2.1 for the proposed ADA parking on the north side of the building, include the dimension for the wheel stop curbing demonstrating the wheel stop curbing is a minimum of 2.5 feet from the front of the parking space to prevent the vehicle from overhanging into the pedestrian circulation. 3. COMMENT: Clarify the intention of the striped area on the north parking area in the northeast corner. 4. COMMENT: Per Technical Standards Manual 7-01.3.4.2.B, when bollards are used to provide physical separation, the maximum separation between the barriers is five feet clear. Dimension the distance between the proposed bollards in the northern parking lot. If you have any questions about this transmittal, Contact Loran Shamis at loran.shamis@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package |
||
08/21/2024 | CDRC Application Completeness | REVIEW COMPLETED | |||
08/26/2024 | CDRC Review Coordinator | REVIEW COMPLETED | No external reviewers are required as it is a site only | ||
09/19/2024 | Fire New Construction | REVIEW COMPLETED | |||
08/26/2024 | OK to Submit - Engineering | REVIEW COMPLETED | |||
08/26/2024 | OK to Submit - Zoning | REVIEW COMPLETED | |||
09/10/2024 | ROW Engineering Review | REVIEW COMPLETED | No comments. | ||
08/27/2024 | Traffic Engineering Review | REVIEW COMPLETED | I cannot foresee any negative impacts to the public right-of-way based on the proposed changes in truck traffic circulation on the site. |