Permit Number - TD-DEV-0723-00334
Review Name: DEVELOPMENT PACKAGE NEW v.4
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
02/15/2024 CDRC Post Review Express PENDING ASSIGNMENT
02/15/2024 Site Zoning REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT: 7075 E 22ND ST- Watermill Express
Development Package (3rd Review)
TD-DEV-0723-00334

TRANSMITTAL DATE: February 15, 2024

DUE DATE: February 29, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM).

Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is August 25, 2024.

2-06.4.0 CONTENT REQUIREMENTS

1. This comment was not addressed. COMMENT: 2-06.4.2.B - Provide a brief legal description within the title block on all sheets.

2. This comment was not addressed correctly. The total number of sheets states “13” but there are only 7 sheets submitted. COMMENT: 2-06.4.2.D - Provide The page number and the total number of pages in the package (i.e., sheet xx of xx) within the title block.

2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided.

3. This comment was not fully addressed. Provide the bearing in degrees, minutes, and seconds for all property lines. COMMENT: 2-06.4.8.A - Provide the site boundary information , including bearing in degrees, minutes, and seconds, with basis for bearing noted, together with distances in feet, to hundredths of a foot, or other functional reference system.

2-06.4.9 - Information on Proposed Development
The following information on the proposed project shall be shown on the drawing or added as notes.

4. This comment was not fully addressed. Clearly demonstrate that the requirements of UDC Article 7.4.6.D.2.b are met for the 2 proposed parallel parking spaces. COMMENT: 2-06.4.9.H.5 – For the two parallel parking spaces the following is required, “A parallel parking space must be eight feet wide and 23 feet in length, except as follows. A parallel parking space can be reduced to 18 feet in length if the space is located immediately adjacent to a driveway , access lane , PAAL , alley , or street intersection and the parking space is designed to provide maneuvering area on at least one end.” When the parking space adjacent to a barrier “ A motor vehicle off-street parking space must have a minimum width of ten feet when the side(s) of the parking space abuts a vertical barrier over six inches in height, other than a vertical support for a carport.

5. This comment was not fully addressed. None of the required information was provided for the proposed kiosks. Existing buildings #1 & #2 provide the heights. There are two existing buildings where none of the required information has been provided. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). Provide the information with the building footprint.

Additional comments:
6. Remove all revision clouds and deltas from the plan.

If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
01/29/2024 CDRC Application Completeness Express REVIEW COMPLETED