Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.3
Permit Number - TD-DEV-0525-00143
Review Name: DEVELOPMENT PACKAGE NEW v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/22/2025 | NPPO Standard | APPROVED | |||
| 09/05/2025 | External Reviewers - Tucson Airport Authority Standard | REQUIRES RESUBMIT | September 4, 2025 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0525-00143, 2 nd Submittal, The proposed development consists of hybrid selfstorage facility with 182 modular storage units placed above grade and a 1-megawatt solar panel system on storage units roof with battery backup. Site improvements will include grading and access drives., 6444 S Fontana Avenue, Tucson, AZ. 85706, Received August 27, 2025 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0525-00143, 2 nd Submittal, a development plan for a new self-storage facility at 6444 S Fontana Avenue. This development is located in the S.E quarter of the S.E. quarter of Section 12, Township 15S, Range 13E, of the Gila and Salt River Meridian. The development site occupies parcel number 138-11-073C, covers approximately 3.24 ± acres, and is zoned as Commercial 2 Zone (C-2). The nearest major roadway intersection is South Fontana Avenue and East Valencia Road, approximately 50 feet to the southeast of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, FAA Part 77 airspace, City of Tucson Airport Environs Overlay Zone - Compatible Use Zone 2, City of Tucson Airport Environs Overlay Zone - Compatible Use Zone 2, City of Tucson Airport Environs Overlay Zone - Noise Control District 65-70, City of Tucson Airport Environs Overlay Zone - Noise Control District 70 Plus, City of Tucson Airport Environs Overlay Zone - Airport Height Overlay Zone (120-140 feet), and City of Tucson Airport Environs Overlay Zone – Airport Hazards Districts. The Tucson Airport Authority is requiring a resubmittal of this project. Conditions of approval: 1. “The applicant shall file two FAA Form 7460-1 with the FAA at least 45 days before construction activities begin unless FAA staff, with the Obstruction Evaluation / Airport Airspace Analysis (OE/AAA), provides the project applicant with written communication that filing FAA Form 7460 is not required. It is highly recommended that the applicant file earlier than 45 days to provide the applicant with sufficient time to respond to any concerns which are identified by the FAA. Any cranes which are used must also be identified with a separate Form 7460. Please file Form 7460 at https://oeaaa.faa.gov/oeaaa/external/portal.jsp The first FAA Form 7460 shall be used for the proposed structures where the solar panels / collection material will be placed. Once the first FAA Form 7460 is submitted, please use the ASN number that is assigned by this first submittal and use it for the second FAA Form 7460 submittal for the solar panels / solar collection materials on the top of the proposed structures.” Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520- 573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning cc file |
||
| 09/22/2025 | External Reviewers - Tucson Electric Power (TEP) Standard | REQUIRES RESUBMIT | TEP review required but not received comments to date, will add on next submittal per Sonya B. ph # 520-730-7979 Sonya.Bermudez@tucsonaz.gov | ||
| 08/07/2025 | ROW Engineering Review Standard | REQUIRES RESUBMIT | TD-DEV-0525-00143 • 6444 S FONTANA AV • V.3 1. Call out the proposed width and dimension location of the proposed sidewalk along Valencia Rd. Reference Section 10-01.4.0 of the UDC Technical Standards. 2. Clearly show and call out the curb opening which will be closed. 3. At the existing curb openings that are proposed to be closed, indicate that the existing post barricades will be removed. 4. Clearly show and label existing and future right of way. The future right-of-way must be taken into account in the design and layout of the development along Valencia Road, reference Section 5.4 of the Unified Development Code. If you have any questions on these comments, please contact Richard Leigh at 520-403-0970 or at richard.leigh@tucsonaz.gov. |
||
| 08/20/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0525-00143 Location: 6444 S FONTANA AV Review Date: 8/20/2025 Site Engineering Comments: 1. This site is designated balanced basin and peak discharge flows will be required to be at or below PRE-development conditions to be compliant. Presented discharge rates show that post-development rates being higher than Pre-development. 2. Show and explain exactly how the recycled concrete is containing the volume presented without it leaving the site above Pre-development rates. 3. What is the achieved capture volume that satisfies the first flush requirements. 4. Provide Hydrologic data sheets that calculate peak discharge PRE and POST development. 5. Revise sight visibility triangles to meet stands as presented in Technical Standards Manual 10–01.5.0 If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 08/22/2025 | Site Landscape Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: HYBRID SELF-STORAGE FACILITY WITH 182 MODULAR STORAGE UNITS -- SITE IMPROVEMENTS WILL INCLUDE GRADING AND ACCESS DRIVES ACTIVITY NO: TD-DEV-0525-00143 ADDRESS: 6444 S FONTANA AV ZONING: C-2 COMMERCIAL ZONE LAND USE: MULTIUNIT STORAGE FACILITY REVIEW 2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Add spot elevations at the top and bottom of the depressed landscape areas or add a leader callout to the grading plan and the planting plan with the corresponding note number on those sheets. 2. The screen section and elevation detail is great. Add the 1 foot offset and 4:1 slope to the foundation side of the screen section detail. Standing water on the concrete could cause issues with the structural integrity of the fence and foundation in the future. 3. Update notes 9 and 10 on the planting plan to be more specific with regard to the inorganic groundcover. It should state that a 2-inch depth layer of screened rock of whatever nominal size you chose and specify a color or state approved equal. IE: 2” depth of ¾” screened rock in Coronado Brown (or approved equal). It should also state that all landscape areas and other disturbed areas on site shall receive this screened rock treatment. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 08/25/2025 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Development Services Department Plans Coordination Office FROM: Krista Hansen – Lead Planner PDSD Zoning Review Section PROJECT: Hybrid Solar Self-Storage, Storage – Personal Storage, C-2 Development Package (2nd Review) TD-DEV-0525-00143 6444 S FONTANA AV TUCSON, AZ 85706 TRANSMITTAL DATE: August 25, 2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is May 21, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) Section 1. Previous comment 9: Provide the square footage and height (measured in feet) of each building and label it on the drawing within the building footprints. **Follow-up to previous comment 9: This comment still stands. On page 6, show building height measured in feet. The minimum setback requirement for the north property line is 1.5 times the height of the proposed structure wall. Based on the wall height of 8’1” (shown as 2458 mm), the minimum setback is 12’1”. The site plans show a setback of 11’4”. Adjust plans to meet setback. 2. Previous comment 19: Indicate if existing streets are public or private; provide street names, widths, curbs, sidewalks, and utility locations, all fully dimensioned **Follow-up to previous comment 19: Add power pole locations to site plan to ensure there is no conflict with pedestrian circulation. 3. Previous comment 20: Per UDC 7.4.6.F.2.b, access lanes and PAALs must be setback at least 2 feet from a wall, screen, or other obstruction over 6 inches. Measurement of all PAAL widths shall not include the 2-feet setback and shall start on the outside edge of any proposed bollards. **Follow-up to previous comment 20: This comment still applies. 4. Previous comment 23: Valancia Rd is a designated MS&R that has a future width of 150 feet. Clearly show future MS&R property line on your plans and add information as noted in the standard above. Remove all buildings and structures that fall within the future ROW. Provide a minimum setback of 10 feet off the future property line. **Follow-up to previous comment 23: This comment still applies. The current right-of-way on Valencia Rd is 120 ft (per paving plan I-85-88). The future MS&R ROW is 150 ft. Remove all buildings and structures that fall within the future ROW (15 ft north of the property line). Provide a minimum setback of 10 feet off the future property line. If you have any questions about this transmittal, Contact Krista Hansen by email Krista.hansen@tucsonaz.gov RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected development package and comment response letter. |
||
| 08/18/2025 | Fire New Construction Standard | REVIEW COMPLETED | -Manual gates require a knox key box. -Electric gates require a knox key switch for fire dept access. john.vincent@tucsonaz.gov 5203495581 |