Permit Number: TD-DEV-0525-00139
Parcel: 131132540

Address:
2524 S WILMOT RD

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0525-00139
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/24/2025 Floodplain Administration Review Standard REQUIRES RESUBMIT See Site Engineering Comments 1. Revise the plan details to delineate the 100-year water surface elevation for the basins. If the distance to the perimeter wall and/or trash enclosure are within 5 ft of said delineation. The Geotech Engineer must provide their recommendations for possible setback requirements. DSSDR 4.14.1 2. Vegetation may be planted on a basin floor or on a basin side slope that is 3:1 or flatter except in areas within a 20-foot radius of the basin inlet, outlet or maintenance access ramp. Plants on the perimeter of a basin shall not obstruct drainage entering or exiting the basin. DSSDR 4.17.1 3. Provide Basin dimensions on grading sheet for proper site inspection
08/21/2025 Site Engineering Standard REQUIRES RESUBMIT Permit: TD-DEV-0525-00139
Location: 2524 S WILMOT RD
Review Date: 8/21/2025
Site Engineering Comments:
1. Revise the plan details to delineate the 100-year water surface elevation for the basins. If the distance to the perimeter wall and/or trash enclosure are within 5 ft of said delineation. The Geotech Engineer must provide their recommendations for possible setback requirements. DSSDR 4.14.1
2. Vegetation may be planted on a basin floor or on a basin side slope that is 3:1 or flatter except in areas within a 20-foot radius of the basin inlet, outlet or maintenance access ramp. Plants on the perimeter of a basin shall not obstruct drainage entering or exiting the basin. DSSDR 4.17.1
3. Provide Basin dimensions on grading sheet for proper site inspection
4. Revise near side sight visibility triangles to meet stands as presented in Technical Standards Manual 10–01.5.0. Golf Links is classified as an Arterial Road.

If you have any questions or concerns, please contact
Marco Contreras
Marco.contreras@tucsonaz.gov
08/29/2025 Site Landscape Standard REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: CONSTRUCTION DOCUMENTS FOR THE FRY'S #33 FUEL CENTER
ACTIVITY NO: TD-DEV-0525-00139
ADDRESS: 2524 S WILMOT RD
ZONING: C-2 COMMERCIAL ZONE
LAND USE: COMMERCIAL FUEL CENTER
REVIEW 3

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape and NPPO Section review comments have been addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Include street landscape border planting calculations for E Golf links Rd.

2. Adjust the depth to be no more than 9 inches in the WHIAs on the water budget table. More than 9 inches requires infiltration testing.

3. The graphic plan view depicting the WHIA appear to be the subwatershed area. WHIA is the basin itself. The square footages for WHIA and Subwatershed as shown on the water budget table appear to be correct and is stating that 72 percent of the plant water needs are being met by this rainwater harvesting plan. Add a note to the commercial rainwater harvesting plan that states: See civil grading plans for grading scheme, spot elevations, cub cut inlets and outlets, downspouts, etc. Please make sure that the above-mentioned grading scheme items are coordinated and simple to reference on sheet C3.10 (GRADING AND PAVING PLAN).

4. Remove the minus designation from the topdressing schedule. The minus/fines material has been misinterpreted on site installations. ¾ inch screened rock in your chosen color will work.

5. The DTM notes look good on the landscape cover sheet. Please include your correspondence/coordination emails or letter of approval from David Marhefka, PLA with DTM for the use of the ROW for required site landscape elements.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
08/25/2025 Site Zoning Standard REQUIRES RESUBMIT Please see comments from Site Engineering; since response to those comment may result in design modifications, Site Zoning will holds approval until those are resolved.