Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.2
Permit Number - TD-DEV-0523-00248
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/05/2023 | Commercial Plumbing | APPROVED | |||
| 11/22/2023 | NPPO | APPROVED | |||
| 12/08/2023 | Site Engineering | APPROVED | |||
| 11/22/2023 | Site Landscape | APPROVED | |||
| 11/17/2023 | Traffic Engineering Review | APPROVED | |||
| 12/11/2023 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 11/21/2023 | Site Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: PDSD Zoning Review PROJECT: Footy Park Development Package (2nd Review) TD-DEV-0523-00248 TRANSMITTAL DATE: November 21, 2023 DUE DATE: December 10, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This plan has been reviewed for compliance with the Unified Development Code (UDC) Administrative Manual (AM) Section 2-06. Also, compliance with applicable development criteria for the proposed use as listed in the City of Tucson Uniform Development Code (UDC) and the UDC Technical Standards Manual (TSM). Section 3.3.3.G.5.c UDC, an applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One-year Expiration date is May 22, 2024. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 1. This comment was not addressed. No barriers have been provided to prevent vehicles from accessing the proposed phase 2 parking area. Based on the new phase line the dumpster will be built in phase 1 but the access to it won’t, clarify how this will work. COMMENT: 2-06.4.9.G – As you are proposing phasing clearly demonstrate how vehicles will be prevented from accessing the Phase 2 area of the plan. Also, as the refuse collection area is shown within Phase 2 demonstrate of refuse collection will be dealt with in Phase 1. 2. Zoning acknowledges that the vehicle parking space calculation has been corrected but until the IPP is approved Zoning cannot approve this DP. COMMENT: 2-06.4.9.H.5.a – The vehicle parking spaces calculation is not correct. Based on the submitted plan there are no courts provided onsite only fields. 3. This comment was not fully addressed. Per UDC Article 7.4.9.B.2.d A single rack is designed and located to accommodate two bicycles. That said, it is not possible to have 9 & 15 space provided. COMMENT: 2-06.4.9.H.5.d - The bicycle parking spaces calculation is not correct. Based on the submitted plan there are no courts provided onsite only fields. 4. This comment was not fully addressed. You state that there are 6 short-term bicycle spaces provided in phase 2 but none are shown on the plan. COMMENT: 2-06.4.9.H.5.d – Show the location of the proposed short-term bicycle parking on the plan. 5. This comment was not addressed. The requirements of UDC Articles 7.4.9.B.1.e, 7.4.9.B.2.f were not addressed. COMMENT: 2-06.4.9.H.5.d – Clearly demonstrate how the requirements of UDC Article 7.4.9.B.1.d & .e, 7.4.9.B.2.a, .f, .g & .h and 7.4.9.C are met for the short-term bicycle parking. 6. This comment was not addressed. Per UDC Article 6.4.5.C.2.b the required street perimeter yard setback is 20’-0”. COMMENT: 2-06.4.9.O – The street perimeter yard setbacks listed are not correct. Review the recent amendments to the UDC found at: https://www.tucsonaz.gov/pdsd/development-code-update, and provide the correct setbacks. 7. This comment was not addressed. Provide the note on the plan.COMMENT: 2-06.4.9.W - Indicate the locations and types of proposed signs (wall, free-standing, pedestal) to assure there are no conflicts with other requirements and that minimal locational requirements can be met. Also provided a note stating all signage requires separate permits. If you have any questions about this transmittal, please contact Nicholas Martell at Nicholas.Martell@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package & detailed response letter. |
||
| 11/21/2023 | Zoning Modifications - IPP | REQUIRES RESUBMIT | Please provide an IPP, sealed by a design professional licensed by the State of Arizona, that includes all the required information as provided in UDC Section 7.4.5.A.4.a-j. If you have questions, email Mark.Castro@tucsonaz.gov | ||
| 11/08/2023 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 12/11/2023 | External Reviewers - Tucson Airport Authority | REVIEW COMPLETED | December 11, 2023 Planning and Development Services City of Tucson 201 North Stone Avenue Tucson, AZ. 85701 RE: TD-DEV-0523-00248, 2 nd Submittal, Development of new commercial soccer facility with parking and landscaping / 1145 S Warren Ave, Tucson AZ 85713, Received November 8, 2023 To whom this may concern, Thank you for the opportunity to comment on TD-DEV-0523-00248, 2 nd Submittal, the development plan for a new commercial soccer facility with parking and landscaping at 1145 S Warren Ave. This development is located in the S.E. corner of the S.E. quarter of Section 18, Township 14S, Range 14E, of the Gila and Salt River Meridian. The development site occupies parcel number 129-08-004B, covers approximately 2.96 ± acres, and is zoned as Residence Zone 2 (R-2), Commercial Zone 3 (C-3), and Light Industrial Zone (I-1). The nearest major roadway intersection is South Warren Avenue and East 22nd Street, approximately 50 feet to the southwest of the subject development. This site does lie within the Tucson International Airport avigation easement requirements and public disclosure area, FAA traffic pattern airspace, and FAA Part 77 airspace. The Tucson Airport approves the 2 nd submittal of this project and is not requiring a resubmit of this project. Please do not hesitate to contact me if you have any questions or concerns regarding this comment letter. I can be reached by email at srobidoux@flytucson.com or by telephone at 520-573-4811. Respectfully, Scott Robidoux, C.M. Manager of Planning |