Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TD-DEV-0426-00094
Parcel: 11309230B

Address:
945 E GRANT RD

Review Status: In Review

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0426-00094
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: In Review
Review Date Reviewer's Name Type of Review Description Status Comments
N/A Commercial Plumbing Standard PENDING ASSIGNMENT
N/A Design Review Standard PENDING ASSIGNMENT
N/A External Reviewers - Tucson Electric Power (TEP) Standard PENDING ASSIGNMENT
N/A Fire New Construction Standard PENDING ASSIGNMENT
N/A NPPO Standard PENDING ASSIGNMENT
N/A ROW Engineering Review Standard PENDING ASSIGNMENT
N/A Site Landscape Standard PENDING ASSIGNMENT
N/A Site Zoning Standard PENDING ASSIGNMENT
04/24/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0426-00094 (1st Review)
Project: The Site will consist of mill and overlay of existing parking lot, restriping of existing parking stalls, ADA parking and accessible routes, and a crosswalk to for ADA routing.
Location: 945 E GRANT RD
Review Date: 4/24/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. Provide the development package case number, TD-DEV-0426-00094, adjacent to the title block on all sheets
2. Provide the page number and total number of pages within the DP (i.e., sheet xx of xx) AD 2-06.4.2. D. This should be progressive on each sheet of the plan set.
3. Provide the Zoning and Land Use General note: “The developer, any successors and assigns, will hold the City of Tucson, its officers, employees, and agents harmless from any and all claims for damages related to the use of this development as shown hereon, now and in the future, by reason of flooding, flowage, erosion, or damage caused by water, whether surface flood or rainfall.” AM 2-06.4.7.B.1
4. Provide the Zoning and Land Use General Note: “Drainage will remain in its natural state and will not be altered, disturbed, or obstructed other than as shown on this site plan.” AM 2-06.4.7.B.3
5. Provide the Zoning and Land Use General Note: “Any relocation or modification of existing utilities and/or public improvements necessitated by the proposed development will be at no expense to the public.” AM 2-06.4.7.D
6. Provide the Zoning and Land Use General Note: “No structure or vegetation shall be located or maintained so as to interfere with the sight visibility triangles in accordance with Section 10-01.5.0, Sight Visibility, of the Technical Standards Manual.” AM 2-06.4.7.C.2
7. Provide the general note: Accessible standards must be met per 2024 IBC, chapter 11, and 2017 ICC A117.1
8. Include this information/text to the keynote relating to the accessible route/sidewalk – Accessible route with 5% maximum running slope and 2% maximum cross slope per 2010 ADA Standards for Accessible Design (ADASAD) Sections 403.3
9. Wheel stops will be required for the new ADA parking spaces per UDC 7.4.6.H
10. Revise Wheel Stop Detail #13 to be compliance with UDC7.4.6.H.3. Wheel stop curbing must be a minimum of two and ½ feet from the front of the parking space. The detail currently shows only 2-feet.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/15/2026 CDRC Application Completeness Express REVIEW COMPLETED
04/20/2026 CDRC Review Coordinator Express REVIEW COMPLETED CDRC added Historic, Design, EP, PAG, USPS, and SWG to the workflow. Review request email sent to TEP. FYI email sent to PAG, USPS, SWG.
04/20/2026 External Reviewers - Pima Association of Governments Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/20/2026 External Reviewers - Southwest Gas Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/20/2026 External Reviewers - United States Postal Service (USPS) Standard REVIEW COMPLETED CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required.
04/22/2026 Historic REVIEW COMPLETED
04/15/2026 OK to Submit - Engineering Fast REVIEW COMPLETED
04/20/2026 OK to Submit - Zoning Fast REVIEW COMPLETED