Permit Number: TD-DEV-0426-00083
Parcel: 12406241A

Address:
10 N PARK AV

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0426-00083
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/06/2026 CDRC Review Coordinator Express PENDING ASSIGNMENT
04/06/2026 Commercial Plumbing Standard PENDING ASSIGNMENT
04/06/2026 Design Review Standard PENDING ASSIGNMENT
04/06/2026 Fire New Construction Standard PENDING ASSIGNMENT
04/06/2026 NPPO Standard PENDING ASSIGNMENT
04/06/2026 ROW Engineering Review Standard PENDING ASSIGNMENT
04/06/2026 Site Engineering Standard PENDING ASSIGNMENT
04/06/2026 Site Landscape Standard PENDING ASSIGNMENT
04/06/2026 Site Zoning Standard PENDING ASSIGNMENT
04/06/2026 OK to Submit - Engineering Fast REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0426-00083 (OK To Submit Review)
Project: Construct temporary facility for Fire Station 3
Location: 10 N PARK AV
Review Date: 4/6/2026
Reviewer: Marco Contreras – Engineering Associate - Site Engineering
Related Cases:

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *
City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf
Site Engineering Review Comments:
1. Application incomplete. Provide the following necessary information:
a. Total Site Area in SQ FT (Acres)
b. The total area of disturbance
c. Provide clarification if grading work is proposed – if so provide associated cut & fill quantities.
d. As the proposed development appears to increase impervious coverage for the site – City of Tucson Balanced basin detention & First flush retention requirements will need to be met addressed. A Drainage report will be required to show full compliance with first flush retention/balanced basin detention requirements. Refer to the Design standards for Stormwater Detention and Retention Chapters 2, 3, & 4. Drainage report content and format requirements can be found in chapter 10 of the DSSDR as well.
e. As drainage requirements will need to be met/addressed, an associated grading plan/sheet will be required to show effective site drainage and compliance with TSM 2-01.0.0.

If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov
04/06/2026 OK to Submit - Zoning Fast REQUIRES RESUBMIT 1. Address Site Engineering comment.
04/03/2026 CDRC Application Completeness Express REVIEW COMPLETED