Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.5
Permit Number - TD-DEV-0425-00097
Review Name: DEVELOPMENT PACKAGE NEW v.5
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/07/2025 | NPPO Standard | APPROVED | |||
| 10/07/2025 | Site Landscape Standard | APPROVED | |||
| 10/16/2025 | Site Zoning Standard | APPROVED | |||
| 09/22/2025 | ROW Engineering Review Standard | REQUIRES RESUBMIT | 1. Driveways should be concrete. TSM Section 10-01.4.3 2. New Sidewalk should be 6' on arterial/collectors. TSM Section 10-01.4.1.A.1.a. 3. Show valley gutter for roadway drainage 4. New driveways do not meet the access management guidelines of 2 per 300', TSMR required. DTM Comment file has been added to attachments. Contact Jesus.Villezcas@tucsonaz.gov if you have any questions |
||
| 09/23/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TD-DEV-0425-00097 Location: 8825 E TANQUE VERDE RD Review Date: 9/23/2025 Site Engineering Comments: 1. The 10x10’ clear space shown on sheet 6 for the trash enclosure detail does not quite measure/show as 10’x10’. Revise according TSM8-01.0.0 2. Add the 2% slope away from the enclosure detail as well as the 1% slope for the concrete pad towards the gate opening in accordance with TSM 8-01.9.0 3. See that ROW Engineering comments are addressed If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |