Permit Number: TD-DEV-0324-00097
Parcel: 10309064B

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.1

Permit Number - TD-DEV-0324-00097
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/17/2024 Commercial Plumbing APPROVED
10/18/2024 Site Zoning APPROVED
10/22/2024 CDRC Post Review PENDING ASSIGNMENT
10/22/2024 Site Engineering REQUIRES RESUBMIT TD-DEV-0324-00097
3760 N COMMERCE DR

Site engineering comments are as follows:
1. The minimum vertical clearance to the bottom of the ADA signage shall be 84” as per TSM 7-01.9.0_Fig. 3. This measurement applies to any freestanding signage. If mounted on the exterior wall of the building, “Signs must be at least 60 inches high measured to the bottom edge so that they are visible while vehicles are parked in a space. Signs can be on posts, or where feasible, on walls... (§307.4))" https://www.access-board.gov/ada/#ada-216_5
2. The minimum width for a standard off street parking space adjacent to any obstruction higher than 6 inches is 10 feet per UDC Article 7.4.6.2.b
3. Ensure the scale for each sheet is accurate. See sheet 4 of 6 on the revised plans as it calls for 1” = 10”. The scale for this sheet is actually 1” = 10’.

Ryan Insalaco
Engineering Associate
City of Tucson
Planning & Development Services Department
Email: ryan.insalaco@tucsonaz.gov
Phone: (520) 837-5351
10/01/2024 CDRC Application Completeness REVIEW COMPLETED
10/08/2024 CDRC Review Coordinator REVIEW COMPLETED No External Reviewers Required
10/17/2024 Fire New Construction REVIEW COMPLETED
10/08/2024 OK to Submit - Engineering REVIEW COMPLETED
10/03/2024 OK to Submit - Zoning REVIEW COMPLETED