Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TD-DEV-0324-00073
Parcel: 11501151C

Address:
355 E SAHUARO ST

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0324-00073
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/24/2024 Site Engineering APPROVED
07/26/2024 Site Landscape APPROVED
07/17/2024 Site Zoning APPROVED
07/26/2024 CDRC Post Review PENDING ASSIGNMENT
07/25/2024 Commercial Plumbing REQUIRES RESUBMIT The sewer structure which was formerly labeled with a rim elevation of 2404.37 is actually a cleanout. The next upstream manhole is located at the intersection of E Sahuaro Street and N 4th Av (MH #9044-07, 2406.11’). On that basis, all three buildings will require backwater valves. Verify that no fixtures located more than 12” above the rim elevation of the next upstream manhole (e.g. fixtures on the second floor) discharge through the backwater valve. Reference: Section 714.1, IPC 2018. [Initial comment: The rim elevation of the next upstream sanitary manhole (2404.32’) is less than 12” below the first floor elevations for buildings 2 and 3 (2404.50’ and 2405.10’). Provide backwater valves for buildings 2 and 3 per Section 714.1, IPC 2018, as amended by the City of Tucson.]
06/21/2024 CDRC Application Completeness REVIEW COMPLETED
07/24/2024 Fire New Construction REVIEW COMPLETED