07/24/2024 | Site Engineering | APPROVED | |||
07/26/2024 | Site Landscape | APPROVED | |||
07/17/2024 | Site Zoning | APPROVED | |||
07/26/2024 | CDRC Post Review | PENDING ASSIGNMENT | |||
07/25/2024 | Commercial Plumbing | REQUIRES RESUBMIT | The sewer structure which was formerly labeled with a rim elevation of 2404.37 is actually a cleanout. The next upstream manhole is located at the intersection of E Sahuaro Street and N 4th Av (MH #9044-07, 2406.11’). On that basis, all three buildings will require backwater valves. Verify that no fixtures located more than 12” above the rim elevation of the next upstream manhole (e.g. fixtures on the second floor) discharge through the backwater valve. Reference: Section 714.1, IPC 2018. [Initial comment: The rim elevation of the next upstream sanitary manhole (2404.32’) is less than 12” below the first floor elevations for buildings 2 and 3 (2404.50’ and 2405.10’). Provide backwater valves for buildings 2 and 3 per Section 714.1, IPC 2018, as amended by the City of Tucson.] | ||
06/21/2024 | CDRC Application Completeness | REVIEW COMPLETED | |||
07/24/2024 | Fire New Construction | REVIEW COMPLETED |