Permit Number: TD-DEV-0225-00040
Parcel: Unknown

Address: Unknown

Review Status: Requires Resubmit

Review Details: DEVELOPMENT PACKAGE NEW v.2

Permit Number - TD-DEV-0225-00040
Review Name: DEVELOPMENT PACKAGE NEW v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/02/2025 CDRC Post Review Express PENDING ASSIGNMENT
04/09/2025 Floodplain Administration Review Standard REQUIRES RESUBMIT Resubmittal comments 9APR25:
1) Add information to the drainage report referencing that the project is located within the Lee Moore Wash Watershed, Tucson Stormwater Management Study (TSMS FWW) Fagan Wash Watershed.
2) Label on Sheet C100 and C109 or other sheet where the extents of the “Public Road” ends.
3) Revise section 4.1 of Drainage report to reflect outcome of scour depth ranging from 2.5 to 4.5 feet deep.
4) On sheet C701, provide concrete curbing at EOP; thickened asphaltic edge is not accepted for floodprone areas.
5) On sheet C701, there are two detail “2”; delete one that does not apply for project.
6) Label arrows on detail 3/C702 as flow or floodplain crossing or other clarification.
7) Add STAtioning to planviews to match scour calculations sheet in Appendix K.
8) Using data derived from Appendix G, show regulatory Floodplain Limits on planviews.
9) Double check proposed flood warning signage locations.
10) Clarify locations of asphalt to assures pavement structural section provides a minimum of three inches of asphaltic concrete supported by minimum of six inches of aggregate base course over additional subgrade structure.
11) Landscaping and SWPP BMP installation may commence, however, no further activities or grading may occur until grading and floodplain use permits are issued.
Elizabeth Leibold P.E., CPM. CFM
Civil Engineer
City of Tucson
520-429-4905
elizabeth.leibold@tucsonaz.gov
05/02/2025 NPPO Standard REQUIRES RESUBMIT CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: IMPROVEMENT OF EXISTING E ANDRADA ROAD FOR A FUTURE SOLAR GENERATION FACILITY
ACTIVITY NO: TD-DEV-0225-00040
PARCEL: 30522004A
ZONING: RH RURAL HOMESTEAD
LAND USE: SOLAR FACILITY
REVIEW #2

This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting.

Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape/NPPO Section review comments have been addressed.

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Coordinate with SWCA Environmental Consultants to include the Native Plant Preservation Plan that has been prepared for the Andrada Road alignment and disturbance areas. With your next submittal, include the NPPP at the end of the Civil Design drawings and show the sheet numbers on the sheet index on the cover sheet.

Thank you.
Chad Keller, RLA
Landscape Architect
chad.keller@tucsonaz.gov
520.837.4923
04/09/2025 Site Engineering Standard REQUIRES RESUBMIT 1. See that floodplain administration comments are addressed.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov