Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW v.1
Permit Number - TD-DEV-0225-00040
Review Name: DEVELOPMENT PACKAGE NEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/14/2025 | Traffic Engineering Review Standard | APPROVED | Traffic Engineering has no comments at this time. | ||
| 03/12/2025 | External Reviewers - Pima County Addressing Standard | NOT REQUIRED | Good afternoon, This project does not require review by Pima County Addressing. Nicholas Jordan Site Review Project Manager II – Addressing Official Pima County Development Services Department 201 N Stone AV – 1st Floor Tucson, AZ 85701 (520) 724-9623 |
||
| 02/25/2025 | Fire New Construction Standard | NOT REQUIRED | |||
| 02/13/2025 | OK to Submit - Zoning Fast | NOT REQUIRED | |||
| 03/04/2025 | ROW Engineering Review Standard | NOT REQUIRED | |||
| 03/19/2025 | Site Landscape Standard | NOT REQUIRED | |||
| 03/18/2025 | Site Zoning Standard | NOT REQUIRED | |||
| 03/28/2025 | CDRC Post Review Express | PENDING ASSIGNMENT | |||
| 03/18/2025 | Floodplain Administration Review Standard | REQUIRES RESUBMIT | 1) Tech Stnd Sec.10-01.3.1: The lease designates the access road approximately 5,700 feet from S Wilmot Rd as a "Public Road" therefore, due to braided floodplain conditions for this watershed, the proposed cross sections for this portion of the access roadway shall all have header curb and asphalt (or concrete) for top portion of the pavement structure. No sidewalk is required. Revise 2, 3, & 4 on plan sheet C701 or other appropriate details on plan sheets. 2) Tech Stnd Sec.4-04.6.6: Provide scour calculations in drainage statement for dip crossing locations to define depth for surface ford concrete walls / header curb / cutoff walls at both sides of each wash dip crossings. 3) Tech Stnd Sec.4-04.10.3.9: Label proposed culverts shall be reinforced concrete, updating table on detail 5 on sheet C701. 4) Tech Stnd Sec.26.40(8): Revise silt fence detail on sheet C700 to not show earth material buildup above grade on upstream side of silt fence - as the build-up can potentially cause redirection of runoff to increase flowrate along silt fence, (instead allowing the silt fence to filter runoff and continue to correct flow direction/pattern), until fence fails at one concentration point. 5) Tech Stnd Sec.4-04.5.2.2: Add note to plans that explains maintenance responsibility of Public Road. 6) UDC sec. 5.7.5.A.4: Address the following comments pertaining to Environmental Resource Zone (ERZ) Overlay Code: a. Label each ERZ floodplain crossing. b. Provide a minimum of six feet in height for vertical clearance over each ERZ watercourse. c. Explain in Drainage Report, how the angled flow will not migrate if the crossing is not perpendicular to flow direction. d. ERZ-ERR report shall be provided as an addendum to the drainage statement. Report shall be organized based on Tech Stnd Sec 4-02.2.5.B.1.a-x. Call for guidance. 7) Tech Stnd Sec.4-04.2.1: Provide a Drainage Statement. Elizabeth Leibold P.E., CPM, CFM, Civil Engineer, City of Tucson 520-429-4905 elizabeth.leibold@tucsonaz.gov |
||
| 03/19/2025 | NPPO Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: CHAD KELLER, RLA SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: IMPROVEMENT OF EXISTING E ANDRADA ROAD FOR A FUTURE SOLAR GENERATION FACILITY ACTIVITY NO: TD-DEV-0225-00040 PARCEL: 30522004A ZONING: RH - RURAL HOMESTEAD LAND USE: SOLAR FACILITY This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all of the Site Landscape/NPPO Section review comments have been addressed. SITE LANDSCAPE/NPPO SECTION COMMENTS: 1. Upon review of aerial images of the site, it appears that protected native vegetation may be present within the proposed alignment of the access road improvement. Please provide a NPPO that shows preservation of existing protected native plants near the grading limits of the road. The preserve in place plants near the grading limit shall include protective fencing linework on the NPPO that depicts the fence placement at or beyond the dripline of the plants being protected in place and a detail of the fence. Since there will be no irrigation water available for transplant and mitigation plant material it is suggested that the viable transplants be placed in a container and offered to local nursery(s) of your choosing as contribution to their reserve stock of protected native plants. Or offered to the City of Tucson Parks Department for their use on current and future projects. This option has not been proposed in the past, but we believe that this effort towards conservation of the protected native plants to be used elsewhere, meets the intent of the Native Plant Preservation Ordinance. If additional information is needed with regard to the NPPO, details, etc., please reach out. My contact information is attached. Thank you. Chad Keller, RLA Landscape Architect chad.keller@tucsonaz.gov 520.837.4923 |
||
| 03/18/2025 | Site Engineering Standard | REQUIRES RESUBMIT | See floodplain administration comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
||
| 02/06/2025 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 02/13/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | CDRC added Addressing and TEP PAG, USPS, SWG to the workflow. Review request email sent to Addressing and TEP. FYI email sent to PAG, USPS, SWG. | ||
| 03/07/2025 | Commercial Plumbing Standard | REVIEW COMPLETED | |||
| 02/13/2025 | External Reviewers - Pima Association of Governments Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 02/13/2025 | External Reviewers - Southwest Gas Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 03/28/2025 | External Reviewers - Tucson Electric Power (TEP) Standard | REVIEW COMPLETED | March 27, 2025 WO#T142219 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Wilmot Energy Center II TD-DEV-0225-00040 Tucson Electric Power Company (TEP) has reviewed and approved the development plan submitted 2/13/2025. There are existing facilities within the development which are depicted upon the plan. There are multiple locations where TEP facilities will be affected by the new development. Relocations of TEP facilities will be required due to grade changes, culvert, drainage and new development locations. Further, there is a pole line on the North side of the Andrada road that is owned by TRICO. Please contact TRICO for a response for their respective facilities. Additionally, please see recorded instruments for existing facilities, attached. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Cruz Vega (520) 349-9850 cruzvega@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
||
| 02/13/2025 | External Reviewers - United States Postal Service (USPS) Standard | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | ||
| 02/11/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 03/12/2025 | ROW Engineering Review Standard | REVIEW COMPLETED | DTM ROW Engineering has no comments at this time. If you have any questions, please contact Richard Leigh at Richard Leigh at richard.leigh@tucsonaz.gov |
||
| 03/07/2025 | Transportation Landscape Review Standard | REVIEW COMPLETED | see comments on plan on file | ||
| 03/07/2025 | Transportation Landscape Review Standard | REVIEW COMPLETED | see comments on plans on file |