Permit Number: TD-DEV-0223-00150
Parcel: 11310001A

Address:
1545 E COPPER ST

Review Status: Requires Resubmit

Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1

Permit Number - TD-DEV-0223-00150
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
09/16/2026 Site Engineering Express REQUIRES RESUBMIT Permit Activity Number: TD-DEV-0223-00150
Project: Rev 1 – Storm Box
Location: 1545 E COPPER ST
Review Date: 9/16/2026
Reviewer: Joe Macaulay – Civil Engineer – Site Engineering
Related Cases: C9-08-16 (PAD-17), DP12-0040, DP12-0088, DP13-0131

*This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. *

City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes
Floodplain Code:
https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333
Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf
Design standards for Stormwater Detention and Retention Link:
https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf

Site Engineering Review Comments:
1. It is unclear with the submitted documentation if the proposed weir and orifice will meet the required developed runoff parameters.
a. Please provide supporting stormwater calculations for the proposed design to ensure the runoff from the 10-year storm is conveyed under the existing sidewalk along E Glenn St.
2. Please add section lines to the Storm Box detail corresponding with sections B-B & C-C.
3. The proposed scupper under the sidewalk along E Glenn St. will need to be completed under a “Work within Right of Way’ permit. This can be started in TDC Online under the current permit (TD-DEV-0223-00150) which will link the ROW permit to this existing permit.
4. As-Built plans for the project will need to be completed and submitted for the constructed work prior to project close-out.
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. For facilitating a shorter review time, please provide updated plans and calculations with a written response to each of the notated items indicating action taken. Do not cloud the changes made for comment updates; revisions are processed if changes occur after the permit is issued. Provide a response letter addressing each comment with location of change on the plans. Submit the separate response letter and plan set files.

If you have any questions or concerns, please contact:
Joe Macaulay at Joe.Macaulay@tucsonaz.gov