Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: In Review
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.2
Permit Number - TD-DEV-0125-00006
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.2
Review Status: In Review
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| N/A | Commercial Plumbing Standard | PENDING ASSIGNMENT | |||
| N/A | New Services/JOC Standard | PENDING ASSIGNMENT | |||
| N/A | Site Zoning Standard | PENDING ASSIGNMENT | |||
| 02/25/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TD-DEV-0125-00006 (1st Review REV 1) Project: New Valvoline - minor auto service building Location: 10096 E OLD VAIL RD Review Date: 2/25/2026 Reviewer: Marco Contreras – Engineering Associate - Site Engineering *This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-6 and Technical Standards Manual (TSM) Section for waste management, Pedestrian Access, Hydrology -Retention/Detention Requirements, and all site standard code. * City of Tucson Code: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes Floodplain Code: https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-19333 Drainage Manual Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/cot-drainage-manual-searchable.pdf Design standards for Stormwater Detention and Retention Link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/engineering-code/updated-retention-detention-manual.pdf Site Engineering Review Comments: 1. The pathway shown connecting to the revised trash enclosure towards the south will need to be revised to be compliant with TSM 7-01.4.1.F a. The reason being that now with this revision, a pedestrian would essentially be walking behind a vehicle which is against TSM 7-01.4.1.F b. Simple solution could be to simply connect to the existing striped area next to the enclosure itself 2. As the two buildings proposed exists and functions on the same “Site,” demonstrate how this new building will connect to the rest of the site per TSM 7-01.3.0 If you have any questions or concerns, please contact Marco Contreras at Marco.contreras@tucsonaz.gov |
||
| 02/20/2026 | CDRC Application Completeness Express | REVIEW COMPLETED | |||
| 02/25/2026 | CDRC Review Coordinator Express | REVIEW COMPLETED | NO EXTERNAL REVIEWERS External Reviewers not required. No further action is required from the customer at this time Site Zoning, Engineering, Water, Entitlements, Commercial Plumbing. |
||
| 02/23/2026 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 02/24/2026 | OK to Submit - Zoning Fast | REVIEW COMPLETED |