Permit Number: TC-UTL-0325-00018
Parcel: 13815015C

Address:
6675 S 12TH AV

Review Status: Requires Resubmit

Review Details: PRIVATE UTILITY v.1

Permit Number - TC-UTL-0325-00018
Review Name: PRIVATE UTILITY v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/21/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/21/2025 Commercial Plumbing - Standard REQUIRES RESUBMIT Provide the rim elevation of the new public manhole, MH#1. Determine the need for a backwater valve per Section 714.1, IPC 2018, as amended by the City of Tucson. If a backwater valve is required, verify that no fixtures located more than 12” above the rim elevation of MH#1 discharge through the backwater valve.
03/20/2025 PDSD Application Completeness Express REVIEW COMPLETED