Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL ADD/ALT v.1
Permit Number - TC-RES-1225-05991
Review Name: RESIDENTIAL ADD/ALT v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/15/2026 | Residential Building - Standard | APPROVED | |||
| 01/15/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/23/2025 | Residential Engineering | REQUIRES RESUBMIT | Permit: TC-RES-1225-05991 Location: 6441 E DUKE DR Review Date: 12/23/2025 Site Engineering Comments: 1. This site resides within a Fema zone X regulatory floodplain and will require the submission and approval of a floodplain use (FPU) permit. The FPU permit is a separate permit that can be submitted within the "sub-records" tab of this associated building permit through TDC online. 2. The FPU permit submission requires submission of a cost estimate for all work performed on the existing residence, the detached carport and fence can be excluded from the estimate. A cost estimate of both materials and labor will be required from the contractor responsible for the project. Break down the total cost into separate lines, separating labor, materials/equipment, and warranties/fees associated with the project. Ensure to have company/contractor letterhead on the document for proper documentation. This cost estimate will be used for substantial improvement calculations. If the project is done as an Owner-Builder, then an OB affidavit is required. 3. Additionally, provide a cost estimate for the installed solar system as this will contribute to the substantial improvement calculations too. 4. Final Site Engineering approval for permit TC-RES-1225-05991 requires review and approval of associated submitted FPU permit. 5. Regarding the fence, flood spacing minimum of 6 inches from natural grade will be required. Flood spacing shall extend the entire length of fence, excluding support members, along the bottom to allow water to flow unobstructed. Please change detail C on A2 of plan set to reflect this. If you have any questions or concerns, please contact Corey Hines Corey.Hines@TucsonAZ.gov |
||
| 12/30/2025 | Residential Zoning | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Roxanne Johnston, Planner PROJECT: TC-RES-1225-05991 6441 E Duke Dr., Tucson, AZ 85710 New Carport, Convert Exist. Carport & 6’ Fencing (1st Review) TRANSMITTAL DATE: 12/30/2025 This site is located within the R-1 zone (UDC 4.7.8). A single-family residence is a permitted use in this zone (Table 4.8-2) subject to Use Specific Standards 4.9.7.B.5 - .9. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Correct plans, as noted in the comments below, along with a response letter indicating how all Site Zoning comments were addressed. 1. What is shown as a temporary shed on Sheet A0 has no permit and sits within the rear and west side perimeter setbacks. For the purposes of determining the perimeter setbacks, show the distance from the shed to the north and west property lines and provide the height of the shed (see Comment 2 on how height is determined). If the shed is not relocated outside of the perimeter setbacks, it will require approval of a DDO since the alley is 20’-wide. Without either relocating the shed out of the setbacks, or the DDO approval, Site Zoning is unable to approve the site plan. To submit an application for a DDO, please use the link and follow the instructions below: www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/boards-committees commissions/drb/012425/ddo-24-81-application-packet.pdf Submit a DDO application under the Zoning Modification sub-record that you will create - for instructions on how to apply for a sub-record, visit the following link: https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/new-pdfs/sub-records_071425.pdf For questions regarding the DDO process, please contact Georgia Pennington at georgia.pennington@tucsonaz.gov 2. UDC 6.4.4.A explains that building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge) of the highest gable of a pitched or hipped roof. Sheet A-3 has not calculated height based on these criteria. Please revise Sheet A-3 to meet the criteria listed in UDC 6.4.4.A and show the correct elevations for the proposed carport and the existing carport to be turned into a living space – from design grade to the top of the wall where it meets the roof. 3. Sheet A0 notes a rusted metal fence to match existing 6’-0” max ht. Please note on the site plan the linear feet and show a diagram of how the height of the fence is measured. 4. Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted for the next review. The City of Tucson Unified Development Code may be accessed here: www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code If you have any questions about this transmittal, please contact Roxanne Johnston at roxanne.johnston@tucsonaz.gov . |
||
| 12/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |