Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-RES-1223-10085
Parcel: 125020980

Review Status: Requires Resubmit

Review Details: RESIDENTIAL SOLAR v.1

Permit Number - TC-RES-1223-10085
Review Name: RESIDENTIAL SOLAR v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/10/2024 Site Engineering NOT REQUIRED
01/10/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
12/27/2023 Light Residential Building Review (OIP) REQUIRES RESUBMIT Permit Review TC-RES-1223-10085 (2901 E HAWTHORNE ST TUCSON, AZ 85716)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2017 National Electrical Code (NEC).

General Review:
1. Provide measurements from the edge of the structure to the property line, R302.1 (City of Tucson Amended).

Electrical Review:
2. Show a Grounding Electrode System at the detached structure per NEC 690.47.
3. Provide Grounding details for the metal structure per NEC 690.43.
4. Provide measurements from the top of the structure to the utility lines. Providing 8’ clearance above the roof/top of the new structure, 2017 NEC 230.24(A). Work with Utilities to verify proper clearance from all overhead lines is approved.
5. The Main Service Panel Upgrade, under permit T21CM09097, was never completed. This permit needs to have its final inspections completed.


Structural Review:
6. Update wind loads per IBC 1609.1.1 (COT Amended): https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2018_-_ibc_amendments.pdf
7. Provide Special Inspection Certificate with parts A and B completed, IBC 1703, 1704. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf
a. SPECIAL INSPECTION FOR HIGH STRENGTH BOLTING IS REQUIRED.
b. SPECIAL INSPECTION FOR DRILLED PIERS/SHAFT IS REQUIRED.

Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
12/27/2023 Site Zoning REQUIRES RESUBMIT FROM: Paul Camarena
PDSD Zoning Review Section

PROJECT: TC-RES-1223-10085
2901 E HAWTHORNE ST Zoning R-1
Solar shade structure

TRANSMITTAL DATE:‎December 27, 2023


COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1.COMMENT: Provide a Residential Plot Plan that meets the requirements found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/permits/residential-permits/residential_plot_plan_requirements.pdf
This shall in include:
a. Lot coverage calculation that meets the requirements of UDC Article 6.4.3 & the example shown on the residential plot requirements. (Lot coverage must include vehicular use area whether improved or unimproved) . Lot coverage does not include porches, UDC Article 6.4.3.C.1.a but does include vehicle use area measured within the outside edges of any area allocated to vehicle use, whether improved or unimproved.

b. Zoning of adjacent parcels
c. All Utility lines
d. Property line distances

2.COMMENT: Provide a dimension a mid-point dimension Per UDC section 6.6.3.D. Accessory structures , except for accessory dwelling units , shall not exceed 12 feet in height, unless attached to a principal structure .
6.4.4.A. Building height is the vertical distance measured from the design grade elevation to the highest point of a flat roof; to the deck line of a mansard roof; or to the middle (between the eave and ridge ) of the highest gable of a pitched or hipped roof, except as follows: (See Figure 6.4.4-A, Measurement of Building Height .)

Additional comment may be forthcoming.


If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov
12/14/2023 PDSD Application Completeness Express REVIEW COMPLETED